Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates
Tunisia

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Poland

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
Tunisia
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Poland
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker
NBG-63 Miniature circuit breaker

NBG-63 Miniature circuit breaker

The NBG-63 Miniature Circuit Breaker (MCB) provides reliable protection against overloads and short circuits in residential, commercial, and industrial power distribution systems. Designed for AC 230/400V circuits and compliant with IEC/EN 60898-1, it ensures high operational safety with positive isolation and stable performance. Available in B, C, and D tripping curves, the NBG-63 offers versatility for different load types and guarantees long mechanical and electrical endurance.

Product Information

Recommend Blogs
NOVEMBER 13, 2026 From Component Search to Panel Layout: Using CHINT Data in the EPLAN Data Portal

Find CHINT components in the EPLAN Data Portal, import part data, and use available macros in schematic and panel-layout workflows.

NOVEMBER 12, 2026 Shunt Reactors in Power Systems: Purpose, Applications, and Selection

Learn how shunt reactors absorb reactive power to manage voltage rise on lightly loaded lines, and what engineers should consider when selecting and applying them.

NOVEMBER 12, 2026 What Instrument Transformers Are Used for: CT and VT Applications

Learn how current transformers (CTs) and voltage transformers (VTs) support metering and protection, and what to consider when selecting and installing them.

OCTOBER 27, 2026 A Practical Guide to Choosing a DIN Rail Power Supply for Industrial Control Panels

Choose a DIN rail power supply for an industrial control panel by checking output load, inrush, environmental derating, protection and PLC compatibility.

OCTOBER 27, 2026 Why Do Capacitor Banks Need Dedicated Switching Contactors?

A capacitor bank does not switch like a motor load. Learn how dedicated capacitor switching contactors manage inrush, switching duty and protection in power factor correction panels.

OCTOBER 27, 2026 Phase Loss and Reversal: How Phase Monitoring Relays Protect Three-Phase Motors

Learn how a phase monitoring relay detects phase loss and phase reversal, how it should be wired into a motor control circuit, and where its protection ends.

OCTOBER 27, 2026 Natural Ester vs. Mineral Oil Transformers: Which Fits Your Project Requirements?

Compare natural ester and mineral oil transformers across fire performance, environmental exposure, temperature behavior, maintenance and project fit.

OCTOBER 26, 2026 Industrial Energy Monitoring: How Smart Meters Cut Waste and Improve Power Reliability

Learn how industrial energy monitoring turns meter data into lower energy waste and stronger power reliability, with CHINT DTSU666-CT and PD7777 options.

OCTOBER 26, 2026 Control Relay Selection and Wiring Guide for Industrial Control Panels

Learn how to select and wire a control relay for an industrial panel, including coil voltage, contact form, load rating, suppression, and CHINT NXJ and NJX12 options.

OCTOBER 26, 2026 How to Select an Electromagnetic Starter for OEM Motor Control Panels

Select an electromagnetic starter for OEM panels by checking motor duty, AC-3 ratings, protection coordination, control options, enclosure, and mounting.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What does the NBG-63 Miniature Circuit Breaker protect against?

It protects electrical circuits from overload and short-circuit faults, preventing damage to wiring and equipment.

 

What are the available tripping curve options?

The NBG-63 is available in B, C, and D curves — B for resistive loads (e.g., lighting), C for mixed or inductive loads (e.g., motors), and D for heavy inductive or high inrush current applications.

 

What is the rated short-circuit breaking capacity of the NBG-63?

It features a breaking capacity of 6kA, ensuring dependable performance in low-voltage systems.

 

In what applications can the NBG-63 be used?

The breaker is ideal for residential, commercial, and industrial distribution boards and control systems, providing safe and efficient protection for various load types

 

How long does the NBG-63 last?

It’s designed for 20,000 mechanical and 10,000 electrical operations, guaranteeing long-term reliability in demanding environments.