Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam

Middle East & Africa

Saudi Arabia
South Africa
UAE
Egypt
Kenya

Europe

France
Kazakhstan
Netherlands
Italy
Spain
Turkey
United Kingdom

North America

Mexico
USA
Canada

Latin America

Brazil
Colombia
Ecuador
Peru

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam
Saudi Arabia
South Africa
UAE
Egypt
Kenya
France
Kazakhstan
Netherlands
Italy
Spain
Turkey
United Kingdom
Mexico
USA
Canada
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
CB-125G Moulded Case Circuit Breaker
CB-125G-MCCB-4P
CB-125G-MCCB-4P Front
CB-125G-MCCB-3P
CB-125G-MCCB-3P Front
CB-125G-MCCB-2P
CB-125G-MCCB-2P Front
CB-125G-MCCB-1P
CB-125G-MCCB-1P Front
CB-125G-MCCB-4P
CB-125G-MCCB-4P Front
CB-125G-MCCB-3P
CB-125G-MCCB-3P Front
CB-125G-MCCB-2P
CB-125G-MCCB-2P Front
CB-125G-MCCB-1P
CB-125G-MCCB-1P Front

CB-125G Moulded Case Circuit Breaker

The CHINT CB-125G Moulded Case Circuit Breaker (MCCB) provides dependable protection against overloads and short circuits in AC power systems up to 415 V and 125 A. With a compact plug-in design, 6 kA breaking capacity, and thermomagnetic trip mechanism, it ensures reliable circuit isolation and control in industrial and commercial environments. Compliant with IEC/EN 60947-2 and certified by CE and TÜV, the CB-125G offers long service life, easy installation, and consistent performance for safe, efficient power distribution.

Product Information

Recommend Blogs
MARCH 10, 2026 How Surge Protective Devices (SPDs) Keep Your Small Business Equipment Safe

Learn how surge protection and electrical protection strategies support small business power needs, reduce downtime, and keep equipment reliable as demand grows.

MARCH 9, 2026 Maintaining Electrical Safety Across Distributed Infrastructure

Learn how smart maintenance strategies protect electrical safety across distributed facilities, reducing downtime and keeping multi-site operations predictable and reliable.

MARCH 8, 2026 How Automated Distribution Systems Improve Network Stability

Grid automation allows for better management of distribution systems and your network. See how automated distribution systems improve outage management.

MARCH 7, 2026 Why Certification Matters in High-Voltage Equipment

Learn why IEC standards and electrical safety certification matter for high-voltage equipment, improving reliability, protection accuracy, and risk control across power networks.

MARCH 6, 2026 Ensuring Continuous Power Supply in Critical Infrastructure Like Airports

Ensure reliable airport power with robust critical power systems and layered resilience. Explore how redundancy, monitoring, and design keep aviation operations running smoothly.

FEBRUARY 14, 2026 Designing with IEC 61439-Compliant Switchgear for Better LV Assembly Performance

Designing an IEC switchboard is necessary for every operation, whether industrial or commercial. Acquiring IEC 61439 design verification for MDBs is important.

FEBRUARY 12, 2026 Selecting the Right Control Components for High-Inrush Loads

Learn how to choose the proper control components like MCCB, overload relay, and contactors used in high inrush load for motor protection.

FEBRUARY 12, 2026 How Smart Meters Help Optimize Building Energy Use

Great building energy management makes use of smart meters to gauge energy consumption. Learn why smart metering is a sign of good energy monitoring practice.

FEBRUARY 3, 2026 Using SCADA Integration to Improve Power Quality

Learn how SCADA integration transforms power quality management in industrial facilities using intelligent controllers, metering systems, and remote monitoring.

FEBRUARY 2, 2026 How Integrated Power Systems Improve Reliability in Industrial Operations

Learn how integrated power systems with power transformers, MV switchgears, and MCCBs help industrial operations by improving reliability and reducing downtime.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the primary function of the CB-125G MCCB?

The CB-125G provides overload and short-circuit protection for AC circuits up to 415 V / 125 A, ensuring system safety and stability.

 

What tripping mechanism does the CB-125G use?

It features a thermomagnetic tripping unit, offering precise protection and reliable fault interruption under varying load conditions.

 

What are its rated breaking and service capacities?

Both Icn and Ics are 6 kA, providing strong performance for standard low-voltage protection applications.

 

How is the CB-125G installed?

The MCCB supports plug-in mounting with top or bottom feed, allowing flexible and efficient panel installation using either cables or busbars.

 

What environments can it operate in?

It performs reliably in −40 °C to +70 °C, at altitudes up to 2,000 m, with an IP20/IP40 protection rating for safe installation in various conditions.