Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
CB-125G Moulded Case Circuit Breaker
CB-125G-MCCB-4P
CB-125G-MCCB-4P Front
CB-125G-MCCB-3P
CB-125G-MCCB-3P Front
CB-125G-MCCB-2P
CB-125G-MCCB-2P Front
CB-125G-MCCB-1P
CB-125G-MCCB-1P Front
CB-125G-MCCB-4P
CB-125G-MCCB-4P Front
CB-125G-MCCB-3P
CB-125G-MCCB-3P Front
CB-125G-MCCB-2P
CB-125G-MCCB-2P Front
CB-125G-MCCB-1P
CB-125G-MCCB-1P Front

CB-125G Moulded Case Circuit Breaker

The CHINT CB-125G Moulded Case Circuit Breaker (MCCB) provides dependable protection against overloads and short circuits in AC power systems up to 415 V and 125 A. With a compact plug-in design, 6 kA breaking capacity, and thermomagnetic trip mechanism, it ensures reliable circuit isolation and control in industrial and commercial environments. Compliant with IEC/EN 60947-2 and certified by CE and TÜV, the CB-125G offers long service life, easy installation, and consistent performance for safe, efficient power distribution.

Product Information

Recommend Blogs
MAY 12, 2026 The Role Of Smart Power Distribution In Reducing Plant Outages

Discover how smart switchgear helps manufacturers cut outages, speed fault isolation, improve power visibility, and support steadier plant operations.

MAY 12, 2026 Retrofitting Commercial Buildings for Power Efficiency

Boost energy savings with retrofit electrical upgrades that sharpen building power quality, lower demand costs, and improve system performance.

MAY 12, 2026 How Digital Substations Support the Smart Grid Transition

A practical guide to turning digital substations into observable, controllable smart grid nodes that improve restoration speed, renewable readiness, and power quality.

MAY 12, 2026 Modular Electrical Distribution for Rapid Deployment

Explore data center electrical design with modular switchgear for faster deployment, stronger uptime, scalable capacity, and simpler maintenance.

MAY 12, 2026 Combining Solar Systems with Smart Switchgear

Safer home PV starts with solar isolators, meters, and breakers that support visibility, fault control, and compliant system design.

APRIL 14, 2026 Creating Energy-Efficient Electrical Installations

Learn how final distribution boards, smart meters, and proper electrical installation design work together to create energy-efficient homes that reduce power waste.

APRIL 14, 2026 Selecting the Appropriate Circuit Breaker for Residential and Industrial Applications

Proper circuit breaker selection entails understanding of circuit breaker types and important selection factors to consider. Learn more in this article.

APRIL 14, 2026 RCCB Tripping Explained: Causes, Nuisance Tripping, and Electrical Fault Diagnosis

In this article, we explain the role of RCCB tripping in electrical safety and what causes unintended or nuisance tripping.

APRIL 14, 2026 Why OEMs Are Standardizing on Modular Breaker Platforms

Learn why OEMs adopt modular circuit breaker platforms to cut engineering time, boost design flexibility, and streamline industrial projects.

APRIL 14, 2026 How to Plan a Fuse Box Upgrade: Costs, MCB Installation, and Safety Benefits

A fuse box upgrade is essential to ensure that your consumer unit can keep up with your current power demand and electric safety needs. Learn more in this article.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the primary function of the CB-125G MCCB?

The CB-125G provides overload and short-circuit protection for AC circuits up to 415 V / 125 A, ensuring system safety and stability.

 

What tripping mechanism does the CB-125G use?

It features a thermomagnetic tripping unit, offering precise protection and reliable fault interruption under varying load conditions.

 

What are its rated breaking and service capacities?

Both Icn and Ics are 6 kA, providing strong performance for standard low-voltage protection applications.

 

How is the CB-125G installed?

The MCCB supports plug-in mounting with top or bottom feed, allowing flexible and efficient panel installation using either cables or busbars.

 

What environments can it operate in?

It performs reliably in −40 °C to +70 °C, at altitudes up to 2,000 m, with an IP20/IP40 protection rating for safe installation in various conditions.