Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)
NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)

NXBLE-63 Residual Current Operated Circuit Breaker (RCBO)

The NXBLE-63 Residual Current Operated Circuit Breaker (RCBO) combines residual current, overload, and short-circuit protection in one compact unit. Designed for AC 50/60Hz systems up to 240/415V, it ensures reliable personal and equipment safety by detecting earth leakage faults while maintaining circuit continuity. With rated currents from 6A to 63A, B and C tripping curves, and breaking capacity up to 6kA, the NXBLE-63 offers enhanced electrical protection and complies with IEC/EN 61009-1 standards for residential, commercial, and industrial power systems.

Product Information

Recommend Blogs
APRIL 15, 2026 Why MCCBs Are Critical for Industrial Safety and Compliance at High Voltage Levels

Does your facility operate with high-voltage industrial applications? Learn how an MCCB can promote electric safety and minimize production downtime in this comprehensive guide.

APRIL 14, 2026 Creating Energy-Efficient Electrical Installations

Learn how final distribution boards, smart meters, and proper electrical installation design work together to create energy-efficient homes that reduce power waste.

APRIL 14, 2026 Selecting the Appropriate Circuit Breaker for Residential and Industrial Applications

Proper circuit breaker selection entails understanding of circuit breaker types and important selection factors to consider. Learn more in this article.

APRIL 14, 2026 RCCB Tripping Explained: Causes, Nuisance Tripping, and Electrical Fault Diagnosis

In this article, we explain the role of RCCB tripping in electrical safety and what causes unintended or nuisance tripping.

APRIL 14, 2026 Why OEMs Are Standardizing on Modular Breaker Platforms

Learn why OEMs adopt modular circuit breaker platforms to cut engineering time, boost design flexibility, and streamline industrial projects.

APRIL 14, 2026 Why Modular Electrical Solutions Offer Faster ROI

Discover how modular electrical systems and prefabricated LV/MV solutions deliver faster ROI through reduced timelines and predictable costs.

APRIL 14, 2026 How to Plan a Fuse Box Upgrade: Costs, MCB Installation, and Safety Benefits

A fuse box upgrade is essential to ensure that your consumer unit can keep up with your current power demand and electric safety needs. Learn more in this article.

APRIL 13, 2026 Common Wiring Mistakes That Reduce Safety in Homes

How do hidden home wiring mistakes impact safety, and why electrical compliance matter? Learn how correct MCB selection reduces risk in modern homes and long-term reliability.

APRIL 13, 2026 How to Install and Use Your Home EV Charger Safely

Learn how to safely manage home charging with expert tips on EV charger installation, daily use, and protective measures for reliable, stress-free charging.

MARCH 10, 2026 How Surge Protective Devices (SPDs) Keep Your Small Business Equipment Safe

Learn how surge protection and electrical protection strategies support small business power needs, reduce downtime, and keep equipment reliable as demand grows.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What does the NXBLE-63 RCBO protect against?

The NXBLE-63 provides comprehensive protection by combining the functions of an MCB (overload/short-circuit) and an RCCB (earth leakage protection) in a single device.

 

In what applications can the NXBLE-63 be used?

It is suitable for residential, commercial, and industrial installations, including power distribution panels, lighting systems, and equipment requiring leakage protection.

 

How do the B and C tripping curves differ?

B Curve (3–5 In): For resistive loads like lighting or heating.

C Curve (5–10 In): For inductive loads such as motors or compressors.

 

What are the rated residual operating current options?

Available in 30mA, 100mA, and 300mA, offering tailored protection levels — from personal safety (30mA) to equipment and fire prevention (300mA).

 

How long is its operational lifespan?

The NXBLE-63 is engineered for over 20,000 mechanical and 4,000 electrical operations, ensuring long-lasting performance and minimal maintenance.