Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
AL-X3 Alarm contact
product-image/new/AL-X3-Accessories (Final Power Distribution)
AL-X3-Accessories (Final Power Distribution)-Front
AL-X3-Accessories (Final Power Distribution)-Side-1
AL-X3-Accessories (Final Power Distribution)-Side-2
product-image/new/AL-X3-Accessories (Final Power Distribution)
AL-X3-Accessories (Final Power Distribution)-Front
AL-X3-Accessories (Final Power Distribution)-Side-1
AL-X3-Accessories (Final Power Distribution)-Side-2

AL-X3 Alarm contact

The CHINT AL-X3 Alarm Contact is an auxiliary signaling device designed for use with NXB-125 series circuit breakers. It provides remote indication of circuit breaker status (ON/OFF/trip) to improve monitoring and safety in electrical systems. When integrated, it signals whether the breaker is manually opened or tripped due to a fault. Built to IEC 60947-5-1 standards, the AL-X3 offers a 10,000-cycle lifespan, high contact reliability, and compact modular design for easy DIN-rail installation.

Product Information

Recommend Blogs
JULY 30, 2026 Automatic Transfer Switch Explained: How Dual Power Switching Keeps Critical Systems Running

Learn how automatic transfer switches detect faults and switch between two power sources to keep hospitals, data centers, and factories running 24/7.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the purpose of the AL-X3 Alarm Contact?

It provides remote indication of circuit breaker status (manual open, close, or trip), enabling fault alarms or status monitoring in electrical panels.

 

Which circuit breakers is it compatible with?

The AL-X3 is designed for use with NXB-125 series circuit breakers, mounted directly to the side via the provided connector system.

 

How does the contact operate during faults?

If the breaker trips due to an electrical fault, terminals 91–92 open while 91–94 close, sending a clear alarm signal to external monitoring systems

 

What installation steps are required?

Remove the left cover of the NXB-125 breaker, attach the AL-X3 module, and mount the assembly on a TH35-7.5 DIN rail.

 

What is its durability and compliance standard?

The AL-X3 meets IEC 60947-5-1 standards and supports up to 10,000 mechanical cycles, ensuring reliable performance in long-term monitoring applications.