Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN

Europe

France
Kazakhstan
Netherlands
Italy
Spain
Turkey
United Kingdom

North America

Mexico

Latin America

Brazil
Colombia
Ecuador
Peru

Choose your country & Language

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
France
Kazakhstan
Netherlands
Italy
Spain
Turkey
United Kingdom
Mexico
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

How to Choose the Right Miniature Circuit Breaker? | CHINT Blog

15 DEC 2022

Table of Contents

  1. How Does a Miniature Circuit Breaker Work?
  2. What are Poles in Circuit Breakers?
  3. Main Parameters of an MCB Breaker
  4. How to Select a Miniature Circuit Breaker?
  5. How to Choose the Right MCB Breaker Current Rating?
  6. Conclusion

Every year, there are about 24,000 home electrical fires in the United States. That’s one for every 14,000 people, roughly. In a town of 50,000 people, there will be four electrical fires. Mini breakers protect the circuits and outlets to which they are attached, tripping when they detect a short or surge.

How Does a Miniature Circuit Breaker Work?

Inside the breaker, there is a metallic strip. If there is a surge in the current, the strip heats up from the flow of electrons. When it reaches a critical level, the strip bends, and breaks. That breakage releases a latch, and the current stops flowing.

In the case of a short circuit, the surge is both immediate and strong instead of gradual. There’s no real-time for the metallic strip to heat up. The short will displace part of the solenoid, and that part will depress the lever that releases the same latch.

What are Poles in Circuit Breakers?

Basically, the difference between the three kinds of breakers is in the current they can handle before tripping. A single-pole breaker can handle 120 volts and between 15 and 20 amperes. They have one metallic strip and one neutral wire.

A double-pole breaker can handle 240 volts and between 20 and 60 amperes. The two poles share a single neutral wire, and each has its own metallic strip. Three-pole breakers generally support the same amperage as double-pole breakers, but the voltage they can handle is up to about 500, making them good for commercial use.

Main Parameters of an MCB Breaker

These breakers all have similar characteristics and are rated at certain levels of voltage and current.

  • Rated voltage: As stated above, the rated voltage indicates what kind of circuits for which the breaker will be useful.
  • Rated current: This is the number of amperes the breaker can handle before tripping.
  • Shell rating current: This is the amount of current that the breaker can handle in totality. If there are multiple short circuit breakers within the shell, then each will have a rating less than the shell. The smaller breakers cannot total more than the shell rating current.
  • Rated breaking capacity and ultimate rating capacity: The rated capacity is assigned by the manufacturer and is based on the current and voltage for which the breaker is rated. The ultimate breaking capacity is the highest amount of current that the breaker can stand and still be operational after breaking three times.
  • Tripping capacity of breakers: These appear on a curve that shows how quickly a circuit breaker will trip when subjected to certain sudden increases in current. Usually, the rating is for double-pole and three-pole breakers, and the starting point for the trip is from the cold state.

How to Select a Miniature Circuit Breaker?

The first things you need to consider are the current and voltage of the circuit. The breaker you choose must be rated at or more than the capacity of the line. Secondly, you need to consider the space into which the breaker will fit.

If you cannot find a breaker that qualifies that will fit into the available space, then you need to change the space to accommodate the breaker you need. You also must determine how many lines need protection. The number of lines must be the same as the number of poles on the breaker.

General Selection Rule

Aside from matching the circuits to the number of poles, you must ensure that the short-circuit breaking capacity is equal to or greater than the capacity of the line. Additionally, the setting current of the MCB must be less than 80% of the short-circuit current at the terminus.

A breaker with multiple poles must also be able to coordinate the breaking of one or more circuits contained within its shell. The breaker should also have an amperage rating that is higher than the device connected to the line and the maximum amperage rating of the line itself.

How to Select a Small Circuit Breaker for Conductor Protection

The load current must be more than the long-delay current. The amount of current that trips instantaneous action must be less than six to 20 times the load current, depending on the circuit.

How to Select a Small Circuit Breaker for Motor Protection

The long-delay current must be equivalent to the motor’s rated current that needs protection. The point of instantaneous reaction must be no more than eight to 15 times that of the motor’s rating for current.

chint next series nxb circuit br 1
chint next series nxb circuit br 1
chint-next-series-nxb-circuit-br-1

How to Choose the Right MCB Breaker Current Rating?

When considering an MCB, there are six basic types: Z, K, D, C, B, and A. Z-rated breakers are the hardest to trip and require the surge to be almost 20 times the rated current of the line. Conversely, A-rated breakers will trip when the surge is only two or three times the rated current of the line. Normally, the first thing you should do is to check if the line is AC or DC. Check the safety protocols for the circuit in question too.

Determine the number of watts the breaker can withstand. Watts = amperage x voltage, or W = I x E. Figure out the demand factor, which is maximum demand load divided by the total connected load. For example, if a home has appliances that generate 10,000 watts when they’re all turned on, but the circuit has a demand maximum of 3,300 watts, then the demand factor is 33%.

The voltage rating of the breaker, or the shell that contains other breakers, will be the final determining factor when choosing a breaker. You certainly don’t want the breaker tripping too often or not enough. Too often will wind up being annoying, while not often enough might wind up being lethal.

Conclusion

At Chint Global, we’ll be able to advise you on the best breakers to use for the circuits you wish to protect. It’s crucial for the safety of your home or small business to have breakers that are not only correct but also up-to-code. Contact us at your earliest convenience, and let us help you.

The Latest
AUGUST 22, 2025 MCCB Frame Sizes Explained: Choosing the Right Circuit Breaker for Industrial Loads

Circuit breakers are important in any electrical system. Learn about MCCB frame sizes to select the correct circuit breaker for industrial loads.

AUGUST 14, 2025 Customized Electrical Components with Better Adaptability, Better Meet Customer Needs

CHINT offers customized OEM electrical solutions with global compliance, fast delivery, and superior adaptability for HVAC, DG, and elevator applications.

AUGUST 11, 2025 From Certification to Application: How CHINT MCCB Supports OEM Success Stories

CHINT M1 MCCB: UL489-certified, high-capacity, versatile breaker powering OEM success in HVAC, solar, industrial & more.

AUGUST 1, 2025 Slim RCBO Solutions for Power Distribution: CHINT NB1L-20 for Compact, Compliant Installations

CHINT’s NB1L-20 is a great addition to any power distribution system. Learn why you should consider our product if you value safety and compliance.

JULY 14, 2025 Why UL Certification is Non-Negotiable for OEMs & Renewable Energy Projects

UL Certification Requirements for OEMs: Essential Guide for Renewable Energy Projects in 2025

JULY 10, 2025 Configuration Guide: Setting Up the CHINT SMG-WSR and SMG-ESR Open Protocol Gateway

Step-by-step protocol gateway setup guide for CHINT SMG-WSR and SMG-ESR, covering wiring, network configuration, and MQTT cloud connection.

JULY 2, 2025 A Guide to the CHINT SMG Open Protocol Gateway: Building Flexible IoT Solutions

Discover how CHINT’s SMG-WSR/SMG-ESR Gateway and NB2 Circuit Breakers create smart, efficient, and remote-controlled electrical systems for various industries.

JULY 1, 2025 An Introduction to Power Circuit Breakers: How Do They Protect Your Industrial and Commercial Facilities?

Explore CHINT’s power circuit breaker solutions for high-performance electrical protection in industrial, commercial, and healthcare environments.

JULY 1, 2025 Understanding the VFD Working Principle in Industrial Automation

Learn the working principle of VFDs and discover how CHINT NVF7 boosts performance, energy savings, and equipment longevity in industrial automation.

JUNE 30, 2025 Gas Insulated Switchgear in Renewable Energy Integration

Learn how CHINT’s gas-insulated switchgear ensures stable, safe, and compact power distribution in renewable energy projects like wind and solar farms.