Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam

Middle East & Africa

Saudi Arabia
South Africa
UAE
Egypt
Kenya

Europe

France
Kazakhstan
Netherlands
Italy
Spain
Turkey
United Kingdom

North America

Mexico
USA
Canada

Latin America

Brazil
Colombia
Ecuador
Peru

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam
Saudi Arabia
South Africa
UAE
Egypt
Kenya
France
Kazakhstan
Netherlands
Italy
Spain
Turkey
United Kingdom
Mexico
USA
Canada
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
RT28
RT28

RT28

The RT28 Cylindrical Contact Caps Fuse Protector is designed for AC 45–62Hz circuits up to 500V, with rated currents up to 63A, providing reliable protection against overload and short-circuit faults. It features a compact modular design for easy installation on TH35-7.5 DIN rails, with gG-type full-range fuse links for superior breaking capacity. Built to IEC 60269-2 and GB/T 13539.2 standards, RT28 offers dependable circuit protection for industrial control panels, power distribution, and lighting systems.

Product Information

Recommend Blogs
MARCH 10, 2026 How Surge Protective Devices (SPDs) Keep Your Small Business Equipment Safe

Learn how surge protection and electrical protection strategies support small business power needs, reduce downtime, and keep equipment reliable as demand grows.

MARCH 9, 2026 Maintaining Electrical Safety Across Distributed Infrastructure

Learn how smart maintenance strategies protect electrical safety across distributed facilities, reducing downtime and keeping multi-site operations predictable and reliable.

MARCH 8, 2026 How Automated Distribution Systems Improve Network Stability

Grid automation allows for better management of distribution systems and your network. See how automated distribution systems improve outage management.

MARCH 7, 2026 Why Certification Matters in High-Voltage Equipment

Learn why IEC standards and electrical safety certification matter for high-voltage equipment, improving reliability, protection accuracy, and risk control across power networks.

MARCH 6, 2026 Ensuring Continuous Power Supply in Critical Infrastructure Like Airports

Ensure reliable airport power with robust critical power systems and layered resilience. Explore how redundancy, monitoring, and design keep aviation operations running smoothly.

FEBRUARY 14, 2026 Designing with IEC 61439-Compliant Switchgear for Better LV Assembly Performance

Designing an IEC switchboard is necessary for every operation, whether industrial or commercial. Acquiring IEC 61439 design verification for MDBs is important.

FEBRUARY 12, 2026 Selecting the Right Control Components for High-Inrush Loads

Learn how to choose the proper control components like MCCB, overload relay, and contactors used in high inrush load for motor protection.

FEBRUARY 12, 2026 How Smart Meters Help Optimize Building Energy Use

Great building energy management makes use of smart meters to gauge energy consumption. Learn why smart metering is a sign of good energy monitoring practice.

FEBRUARY 3, 2026 Using SCADA Integration to Improve Power Quality

Learn how SCADA integration transforms power quality management in industrial facilities using intelligent controllers, metering systems, and remote monitoring.

FEBRUARY 2, 2026 How Integrated Power Systems Improve Reliability in Industrial Operations

Learn how integrated power systems with power transformers, MV switchgears, and MCCBs help industrial operations by improving reliability and reducing downtime.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the RT28 Cylindrical Contact Caps Fuse Protector used for?

It’s designed for AC circuits up to 500V to protect against overload and short-circuit faults in lighting systems, industrial control panels, and low-voltage distribution boards.

 

What is the function of the neon indicator (“X” type)?

The “X” version includes a built-in neon light that provides a visual signal when the fuse link has blown, enabling quick maintenance without removing the protector.

 

Can the RT28 be installed in high-altitude areas?

Yes, but current ratings should be derated: 0.9×In at 2500m and 0.8×In at 3000m, ensuring reliable operation under reduced air pressure.

 

What’s the difference between RT28-32 and RT28-63 models?

RT28-32 supports fuse links up to 32A (10×38mm), while RT28-63 supports up to 63A (14×51mm). Both share the same modular structure but differ in size and rated current range.

 

Is the RT28 suitable for use in capacitor banks?

It’s not recommended for capacitor circuits; RT36-00 Fuse Protector is advised instead.