Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

Saudi Arabia
South Africa
UAE
Egypt
Kenya

Europe

France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom

North America

Mexico
USA
Canada

Latin America

Brazil
Colombia
Ecuador
Peru
Low-voltage
Instruments and Meters
EV Charging
Telecom & Data Center
Buildings
Products
Solutions
Project References
Corporate Reports
CHINT Global
CHINT's Insights
Careers
Locate Us
Contact Us
Call Us +65 6329 3110
Email Us sales.apac@chint.com
Privacy Policy
Online Services

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
Saudi Arabia
South Africa
UAE
Egypt
Kenya
France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom
Mexico
USA
Canada
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

How to Install NXR-38 Thermal Overload Relay

FEB 17, 2025

Install NXR-38 Thermal Overload Relay
Install NXR-38 Thermal Overload Relay
Install NXR-38 Thermal Overload Relay

Table of Contents

  1. Preparation
  2. Installation Steps
  3. Wiring Instructions
  4. Testing Steps
  5. Fault Diagnosis and Troubleshooting
  6. Summary

Thermal overload relays are valuable devices. They help protect electrical motors from potential damage. It’s specifically the damage caused by excessive current. The NXR-38 Thermal Overload Relay is a popular device in this category. It monitors motor current and prevents overheating. This guide provides thorough instructions for installing, commissioning, operating, and troubleshooting the NXR-38 relay. The goal is to help you ensure safe and efficient motor operation.

Preparation

Follow the following preparation steps for a smooth and safe setup of this 3 phase overload relay:

1. Safety Precautions

Always prioritize safety during installation. Disconnect the power source. Wear insulating gloves and protective goggles.

2. Tool Checklist

Here’s what you’ll need for a successful thermal overload relay installation:

  • Wire strippers
  • Crimping tools
  • Screwdrivers
  • Multimeter
  • Appropriate wires
  • Wire lugs
  • Insulated gloves
  • Protective goggles
Install NXR-38 Thermal Overload Relay
Install NXR-38 Thermal Overload Relay
Install NXR-38 Thermal Overload Relay

Installation Steps

Following these steps for proper mounting and connection of the NXR-38 Thermal Overload Relay:

1. Inspection

Before installation, verify that the STOP, RESET, and TEST buttons function normally.

2. Mounting

Carefully attach the AC contactor actuator to the DIN rail. Align the top edge first, then press down firmly to secure the bottom. Then, use a screwdriver to remove the AC contactor terminals 2/T1, 4/T2, and 6/T3.

3. Connecting the Relay

Hang the rear cover hook of the thermal overload relay into the slot of the AC contactor. Precisely align the three conductive rods of the thermal relay 1/L1, 3/L2, and 5/L3 with the terminals of the AC contactor. Press the rods into position. Then tighten the securing screws with a screwdriver.

4. Adjust Current Setting

The current setting is crucial for thermal overload protection. Calibrate the adjustment cam to match the specific working conditions of your motor.

Wiring Instructions

Proper wiring is critical to the relay’s performance and overall system reliability. Follow these recommendations and guidelines:

1. Wire Selection

Choose wires with appropriate cross-sectional areas based on the current rating. This ensures optimal electrical conductivity and safety of the overload relay thermal unit. Refer to this table for the correct selection:

Rated Current (In)

Wire Cross-Section (S (Cu) mm²)

12A

1 ~ 4

25A

1 ~ 6

38A

4 ~ 10

100A

4 ~ 35

2. Wire Preparation

Strip insulation to the specified length and crimp wire lugs securely:

  • For primary circuit wiring, strip 11 to 13 millimeters.
  • For auxiliary circuit wiring, strip 9 to 11 millimeters.

3. Wiring Guidelines

Create clear physical separation between primary and auxiliary circuits. Use cable management techniques to route wires. For NXR-38 auxiliary contact terminals 95 96 (NC or Normal Close Contact) connect in the same loop with contactor terminals A1 A2. Terminals 97 and 98 are Normal Open Contacts (NO).

Use a calibrated torque screwdriver to tighten electrical connections. Follow recommended torque values for each specific terminal type. These include:

Fastening Screw Size

M3.5

M4

Tightening Torque (N.m.)

0.8

1.7

Testing Steps

Thorough testing is essential to verify the relay’s proper installation and functionality. There are two key checks:

1. Pre-Power Check

Verify the status of the STOP, RESET, and TEST buttons before powering up the system.

2. Post-Power Test

Use a multimeter to perform continuity checks and confirm the normal operation of the thermal overload relay.

Fault Diagnosis and Troubleshooting

Despite careful installation, a thermal overload relay can occasionally encounter operational issues. The following table provides a comprehensive overview of common symptoms, their potential causes, and recommended troubleshooting methods:

Symptom

 

Potential Causes

Troubleshooting Methods

Thermal Relay Malfunctions Without Overload

 

Incorrect model selection (too small)

Replace with a larger specification product

The current value set lower than the motor’s operating current

Adjust the cam clockwise to match the actual motor current

Strong mechanical shocks or vibrations

Inspect the installation site. Ensure the relay is not in a high-impact environment

Frequent motor starts

Limit motor start frequency to 30 starts per hour

Inadequate wire connections

Use standard wire sizes. Ensure proper connection torque settings

Thermal Relay does not Operate

Incorrect model selection (too large)

Replace with a smaller specification product

The current value is set higher than the motor current

Adjust the cam counterclockwise to match the motor current

Oversized wire cross-section

Use appropriate wire sizes and also apply proper torque settings

Thermal Relay does not Operate

Relay reset mechanism failure

Press the RESET button firmly

Auxiliary contacts not conducting

Replace the thermal relay

Main or auxiliary circuit damage

Replace the thermal relay

 

Summary

Installing the NXR-38 Thermal Overload Relay requires careful preparation and precise installation. Thorough testing is crucial to ensure proper operation. By following these relay installation guidelines, you can ensure reliable motor protection and optimal performance. At CHINT, we offer reliable electrical solutions. Browse our website to access our detailed documentation.

The Latest
MARCH 10, 2026 How Surge Protective Devices (SPDs) Keep Your Small Business Equipment Safe

Learn how surge protection and electrical protection strategies support small business power needs, reduce downtime, and keep equipment reliable as demand grows.

MARCH 9, 2026 Maintaining Electrical Safety Across Distributed Infrastructure

Learn how smart maintenance strategies protect electrical safety across distributed facilities, reducing downtime and keeping multi-site operations predictable and reliable.

MARCH 8, 2026 How Automated Distribution Systems Improve Network Stability

Grid automation allows for better management of distribution systems and your network. See how automated distribution systems improve outage management.

MARCH 7, 2026 Why Certification Matters in High-Voltage Equipment

Learn why IEC standards and electrical safety certification matter for high-voltage equipment, improving reliability, protection accuracy, and risk control across power networks.

MARCH 6, 2026 Ensuring Continuous Power Supply in Critical Infrastructure Like Airports

Ensure reliable airport power with robust critical power systems and layered resilience. Explore how redundancy, monitoring, and design keep aviation operations running smoothly.

FEBRUARY 14, 2026 Designing with IEC 61439-Compliant Switchgear for Better LV Assembly Performance

Designing an IEC switchboard is necessary for every operation, whether industrial or commercial. Acquiring IEC 61439 design verification for MDBs is important.

FEBRUARY 12, 2026 Selecting the Right Control Components for High-Inrush Loads

Learn how to choose the proper control components like MCCB, overload relay, and contactors used in high inrush load for motor protection.

FEBRUARY 12, 2026 How Smart Meters Help Optimize Building Energy Use

Great building energy management makes use of smart meters to gauge energy consumption. Learn why smart metering is a sign of good energy monitoring practice.

SEPTEMBER 23, 2025 Manual Motor Starter: A Guide for Safer Motor Control

Every electric motor needs protection against fault conditions. In this article, learn how a manual motor starter helps you achieve this requirement.

AUGUST 1, 2025 Slim RCBO Solutions for Power Distribution: CHINT NB1L-20 for Compact, Compliant Installations