Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN

Europe

France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom

North America

Mexico

Latin America

Brazil
Colombia
Ecuador
Peru

Choose your country & Language

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom
Mexico
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

How NM8N-HV MCCB Protects AC Outputs of Solar Systems

MAY 6, 2025

NGC5 Original Manufactured LV Switchgear
NGC5 Original Manufactured LV Switchgear
NGC5 Original Manufactured LV Switchgear

  Table of Contents                                                

  1. Key Features
  2. Applications
  3. Typical Panel Schemes

NGC5 Original Manufactured LV Switchgear is the brand new type test assembly crafted by CHINT. As the heart of low voltage power distribution system, NGC5 sets a new benchmark for reliability and efficiency.

Safe and Reliable

NGC5 has been thoroughly tested and certified, holding certifications like CE certification and TUV test report.

It has successfully passed a range of environmental and safety tests, including 200-hour salt mist test, 4500 meters high-altitude test, and internal arc fault test rated at 100kA for 1 second.

Furthermore, the main busbar system is fully enclosed within an isolated compartment, providing complete separation from other functional units and minimizing the possibility of internal faults.

Flexible & Versatile

Designed to adapt to various scenarios, NGC5 supports protection degrees ranging from IP30 to IP43, and offers compatibility with rated operating voltages of 400V, 415V, 480V, and 690V.

NGC5 rated current can be up to 6300A with a flexible busbar design and is suitable for both 50Hz and 60Hz power frequency applications.

NGC5 also provides various panel schemes, including Fixed panel, Fixed separation panel, Drawer panel, APFC panel, etc.

These features make NGC5 highly adaptable to various regional standards and specific segment requirements.

Efficient & Cost-effective

With its modular structure and factory pre-assembly, NGC5 helps reduce on-site installation time and labor costs. With a stable and consistent supply chain, the lead time can be shortened within 2 months.

NGC5 Original Manufactured LV Switchgear plays a vital role across a wide range of scenarios. Typical applications as below:

  • Building: ensure safe and efficient power distribution in office buildings and shopping malls alike.
  • Industrial Park: provide reliable power management for manufacturing plants and heavy machinery.
  • Transportation: support the control and distribution of power for signaling, lighting, and station systems.
  • Data Center: maintain stable and uninterrupted power supply to sensitive IT equipment.

As an original manufactured LV Switchgear, NGC5 is manufactured in CHINT's own factories. CHINT's integrated power distribution industry is centered on its Jiaxing factory. Jiaxing factory mainly focuses on manufacturing of advanced low-voltage and medium-voltage intelligent integrated power distribution panels. It began construction in October 2019, covering a construction area of 72,000 square meters, and investing in 1,136 sets of advanced digital production equipment.

NGC5 typical panel schemes as below:

Fixed panel scheme:

  • Mainly used as incoming panel, outgoing panel, tie panel.
  • The maximum main busbar current can be up to 6300A, and the rated short-time withstand current can be up to 100kA/1s.
  • The entry method can be top/bottom.

Fixed separation panel scheme:

  • The maximum current of the distribution busbar can be up to 3200A.
  • It has strict internal separation, which is safer for people.
  • The main busbar is uniformly arranged on the top of the switchgear, with a high degree of standardization.
  • The distribution busbar can be arranged in the front side and rear side of the panel, which is simple and convenient for installation and maintenance.

APFC panel scheme:

  • It can realize intelligent harmonic removal, dynamic reactive power compensation, and balanced three-phase load functions.
  • Modular design for easy commissioning and maintenance.
  • Exclusive cooling channel.

Drawer panel scheme:

  • It can achieve the compactness, diversity, and flexibility of panel solutions.
  • The minimum unit can be 8E/4 drawers, a single panel can be installed with a maximum of 36 units, the maximum distribution busbar current can be up to 1800A.
  • The configuration is flexible, can achieve front and rear maintenance, and can realize the mixed structure of drawers and fixed separation units.

NGC5—raises the bar with modular, standardized, and smart designs that deliver enhanced safety, efficiency, and flexibility. Get in touch with us today to learn more about our switchgear solutions.

The Latest
JUNE 12, 2025 What Is Motor Start Up Current and Why Is It So High?

Discover why motor start-up current is so high and how it affects electrical systems. Learn how to protect motors effectively with CHINT's solutions.

JUNE 12, 2025 Selecting the Right Air Circuit Breaker for Data Centers and Critical Power Distribution

Discover how to select the right air circuit breaker for data centers. Learn about CHINT’s NA8 features, certifications, and smart integration benefits.

JUNE 11, 2025 Everything You Should Know About Solar Pumping System

Understand the benefits, applications, and components of solar pumping systems including CHINT’s NVFPV drives for reliable water access.

JUNE 10, 2025 How Altitude Affects the Performance of Moulded Case Circuit Breakers

Learn the effects of altitude on circuit breakers and explore CHINT’s NM8N-HV MCCB built for extreme conditions with high performance and safety.

JUNE 9, 2025 What Is A Pulse Relay and How Does It Work?

Explore the energy-efficient pulse relay technology used in automation, lighting, and security systems. Featuring CHINT’s NJMC1 relay for reliable performance.

JUNE 7, 2025 Understanding AC Contactors: Uses and Warning Signs of Failure

Learn how to recognize signs of a failing AC contactor and get expert tips on resolving issues, performing maintenance, and ensuring electrical safety.

JUNE 6, 2025 What Are Harmonics and Total Harmonic Distortion (THD) in Power Systems

Discover the causes, impacts, and solutions for harmonics and THD in electrical networks. Enhance reliability with CHINT’s NZB379 controller.

JUNE 6, 2025 Types of Lightning Surge Arresters and Their Functions

Discover the essential types of lightning surge arresters and their working principles. Learn how to protect your electrical systems from voltage surges effectively.

JUNE 5, 2025 Automatic Transfer Switch (ATS) Comprehensive Guide

Explore how ATS ensures uninterrupted power supply for critical applications. Learn about types, uses, performance, and CHINT solutions.

JUNE 5, 2025 Thermal Magnetic Circuit Breakers vs Hydraulic Magnetic Circuit Breakers

A comprehensive comparison of thermal magnetic and hydraulic magnetic circuit breakers. Learn about their protection, environmental susceptibility, trip time, size, and cost with CHINT.