Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

Saudi Arabia
South Africa
UAE
Egypt
Kenya

Europe

France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom

North America

Mexico
USA
Canada

Latin America

Brazil
Colombia
Ecuador
Peru
Low-voltage
Instruments and Meters
EV Charging
Telecom & Data Center
Buildings
Products
Solutions
Project References
Corporate Reports
CHINT Global
CHINT's Insights
Careers
Locate Us
Contact Us
Call Us +65 6329 3110
Email Us sales.apac@chint.com
Privacy Policy
Online Services

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
Saudi Arabia
South Africa
UAE
Egypt
Kenya
France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom
Mexico
USA
Canada
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NXB-63G Moulded Case Circuit Breaker
NXB 63G 32A-2P-MCB-1
NXB 63G 32A-2P-MCB-3
NXB 63G 32A-2P-MCB-5
NXB 63G 32A-2P-Orange Stem-MCB-10
NXB 63G 32A-2P-Orange Stem-MCB-7
NXB 63G 32A-2P-Orange Stem-MCB-9
NXB 63G 32A-3P-MCB-1
NXB 63G 32A-3P-MCB-3
NXB 63G 32A-3P-MCB-5
NXB 63G 32A-3P-Orange Stem-MCB-10
NXB 63G 32A-3P-Orange Stem-MCB-7
NXB 63G 32A-3P-Orange Stem-MCB-9
NXB 63G 32A-4P-MCB-1
NXB 63G 32A-4P-MCB-3
NXB 63G 32A-4P-MCB-5
NXB 63G 32A-4P-Orange Stem-MCB-10
NXB 63G 32A-4P-Orange Stem-MCB-7
NXB 63G 32A-4P-Orange Stem-MCB-9
NXB 63G 32A-MCB-Side-1
NXB 63G 32A-Orange Stem-MCB-Side-3
NXB-63G-Bule Stem-MCB-1
NXB-63G-Bule Stem-MCB-5
NXB-63G-Bule Stem-MCB-Front-7
NXB 63G Bule Stem MCB Side 3
NXB 63G Orange Stem MCB 1
NXB-63G-Orange Stem-MCB-3.
NXB-63G-Orange Stem-MCB-Front-6
NXB-63G-Orange Stem-MCB-Side-4
NXB 63G 32A-2P-MCB-1
NXB 63G 32A-2P-MCB-3
NXB 63G 32A-2P-MCB-5
NXB 63G 32A-2P-Orange Stem-MCB-10
NXB 63G 32A-2P-Orange Stem-MCB-7
NXB 63G 32A-2P-Orange Stem-MCB-9
NXB 63G 32A-3P-MCB-1
NXB 63G 32A-3P-MCB-3
NXB 63G 32A-3P-MCB-5
NXB 63G 32A-3P-Orange Stem-MCB-10
NXB 63G 32A-3P-Orange Stem-MCB-7
NXB 63G 32A-3P-Orange Stem-MCB-9
NXB 63G 32A-4P-MCB-1
NXB 63G 32A-4P-MCB-3
NXB 63G 32A-4P-MCB-5
NXB 63G 32A-4P-Orange Stem-MCB-10
NXB 63G 32A-4P-Orange Stem-MCB-7
NXB 63G 32A-4P-Orange Stem-MCB-9
NXB 63G 32A-MCB-Side-1
NXB 63G 32A-Orange Stem-MCB-Side-3
NXB-63G-Bule Stem-MCB-1
NXB-63G-Bule Stem-MCB-5
NXB-63G-Bule Stem-MCB-Front-7
NXB 63G Bule Stem MCB Side 3
NXB 63G Orange Stem MCB 1
NXB-63G-Orange Stem-MCB-3.
NXB-63G-Orange Stem-MCB-Front-6
NXB-63G-Orange Stem-MCB-Side-4

NXB-63G Moulded Case Circuit Breaker

The NXB-63G Moulded Case Circuit Breaker (MCCB) offers overload protection, short-circuit protection, and positive isolation for diverse electrical systems. Its dependable performance and adaptable design make it an indispensable solution for power distribution and equipment protection in commercial, industrial, and specialized residential applications.

Product Information

Recommend Blogs
MAY 12, 2026 Retrofitting Commercial Buildings for Power Efficiency

Boost energy savings with retrofit electrical upgrades that sharpen building power quality, lower demand costs, and improve system performance.

MAY 12, 2026 The Role Of Smart Power Distribution In Reducing Plant Outages

Discover how smart switchgear helps manufacturers cut outages, speed fault isolation, improve power visibility, and support steadier plant operations.

MAY 12, 2026 Modular Electrical Distribution for Rapid Deployment

Explore data center electrical design with modular switchgear for faster deployment, stronger uptime, scalable capacity, and simpler maintenance.

MAY 12, 2026 How Digital Substations Support the Smart Grid Transition

A practical guide to turning digital substations into observable, controllable smart grid nodes that improve restoration speed, renewable readiness, and power quality.

MAY 12, 2026 Combining Solar Systems with Smart Switchgear

Safer home PV starts with solar isolators, meters, and breakers that support visibility, fault control, and compliant system design.

APRIL 14, 2026 Creating Energy-Efficient Electrical Installations

Learn how final distribution boards, smart meters, and proper electrical installation design work together to create energy-efficient homes that reduce power waste.

APRIL 14, 2026 Selecting the Appropriate Circuit Breaker for Residential and Industrial Applications

Proper circuit breaker selection entails understanding of circuit breaker types and important selection factors to consider. Learn more in this article.

APRIL 14, 2026 RCCB Tripping Explained: Causes, Nuisance Tripping, and Electrical Fault Diagnosis

In this article, we explain the role of RCCB tripping in electrical safety and what causes unintended or nuisance tripping.

APRIL 14, 2026 Why OEMs Are Standardizing on Modular Breaker Platforms

Learn why OEMs adopt modular circuit breaker platforms to cut engineering time, boost design flexibility, and streamline industrial projects.

APRIL 14, 2026 How to Plan a Fuse Box Upgrade: Costs, MCB Installation, and Safety Benefits

A fuse box upgrade is essential to ensure that your consumer unit can keep up with your current power demand and electric safety needs. Learn more in this article.

Helpful Links

Blog
Blog

Explore expert insights, trends, and CHINT perspectives on the smart energy industry.

Read More
Resources
Resources

Download essential CHINT resources for your business needs.

Download Now
Contact Us
Contact Us

Have questions? Contact us for support and solutions.

Get Support
Collapsed
Expand

FAQs

 

What protection functions does the NXB-63G MCCB offer?

It provides overload, short-circuit, and isolation protection for low-voltage circuits, ensuring safe and efficient power distribution.

 

What is the breaking capacity of this MCCB?

The NXB-63G has a rated breaking capacity (Icu) of 6kA, ensuring dependable interruption of fault currents up to this limit.

 

What environments is this circuit breaker suitable for?

It operates effectively between −35°C and +70°C, making it suitable for residential, commercial, and light industrial installations.

 

What tripping options are available?

Two instantaneous trip settings — 10In and 14.2In — provide flexible protection for different types of electrical loads.

 

How long is its service life?

The breaker is rated for 20,000 mechanical and 10,000 electrical operations, ensuring long-term durability and reliability.