Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN

Europe

France
Italy
Spain
Turkey
Kazakhstan
Netherlands

North America

Mexico

Latin America

Brazil
Peru
Ecuador
Utility PV & ESS

Choose your country & Language

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
France
Italy
Spain
Turkey
Kazakhstan
Netherlands
Mexico
Brazil
Peru
Ecuador

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

How to Install JKF8-12 Intelligent LV Reactive Power Auto Compensation Controller

JAN 14, 2025

JKF8-12 Compensation Controller
JKF8-12 Compensation Controller
JKF8-12 Compensation Controller

Table of Contents

  1. Necessary Tools for the Installation
  2. Installation Steps
  3. Observe Whether the Product is Working Normally
  4. Conclusion

The JKF8-12 is an intelligent low-voltage reactive power auto compensation controller. This sophisticated device helps improve power quality and reduce energy losses. It enhances overall electrical network efficiency. This article provides a comprehensive installation guide. It aims to help you safely install this device and troubleshoot it to ensure optimal performance and reliability.

Necessary Tools for the Installation

Installing the JKF8-12 compensation controller requires careful preparation and the right equipment. The essential tools include:

  • Insulated Gloves: They protect against electrical hazards and ensure personal safety.
  • Wire Strippers: These precisely remove insulation from electrical wires.
  • Wire Crimping Pliers: They securely attach wire noses and ensure reliable connections.
  • Wires of Appropriate Specifications: The goal is to match LV controller requirements for proper functionality.
  • Wire Noses: These facilitate clean and secure wire connections.
  • Screwdrivers (electric, hand): These enable precise screw tightening and terminal connections.
  • Multimeter: It helps to verify electrical connections and diagnose potential issues.

Installation Steps

Follow these guidelines for a successful installation of the JKF8-12 compensation controller:

1. Pre-Installation Check

Before starting, thoroughly review the specifications and compatibility of the LV controller with your existing electrical infrastructure. Verify that all system parameters align with the JKF8-12’s requirements.

2. Controller Mounting

Select an appropriate location within the electrical cabinet. Make sure there’s sufficient ventilation and protection from environmental factors. The mounting area should have a size of 113x113mm and provide easy access for future maintenance. The ambient temperatures should be between -10°C to +55°C. Relative humidity should not exceed 90% to prevent potential performance degradation.

3. Fastening the Controller

Use the provided mounting accessories to securely attach the controller. Ensure stable positioning using the designated mounting holes and fastening screws. Apply gentle torque to mounting screws to prevent over-tightening while maintaining secure attachment. Rotate the screw on the accessory clockwise.

4. Wiring Identification

Carefully identify and map out all necessary wire connections. Double-check each LV controller connection point to prevent potential errors during the installation process. Utilize the controller’s standard color-coding system for ease of wiring setup.

5. Wire Preparation

Strip wire ends with precision. Make sure that the copper length is appropriately exposed. The exposed copper wires should be 1.5mm² for voltage and control outputs and 2.5mm² for current sampling. Then, use wire crimping pliers to attach wire noses.

6. Connection of Ports and Terminals

Connect specific ports and terminals of the compensation controller according to the detailed wiring diagram. Pay close attention to voltage, control outputs, and current sampling requirements of compensating controls. Ensure connections to ports 1-12 for respective capacitor bank switching contactors. Also, ensure proper mapping of com, US2, and US1 to power supplies L1, L2, and L3 respectively.

7. Tightening

Finally, use a hand screwdriver to securely tighten all wire connections of the compensation controller. Tighten the wires until the screws reach the end.

Observe Whether the Product is Working Normally

After completing the installation, it’s critical to verify the operational status of the compensation controller. Carefully observe the system’s performance and monitor its initial functioning.

Should you encounter any issues, our comprehensive troubleshooting guide offers solutions to common problems. The following are a couple of common troubleshooting scenarios and suggestion solutions:

1. Undercurrent Status Display

Symptom: Controller consistently displays an undercurrent status "≡1.

Potential causes

Troubleshooting methods and precautions

The sampling current may be less than 150mA or the secondary circuit of the current transformer may be open

Check the sampling transformer and its secondary circuits for potential openings

Potential fault in sampling transformer or controller

If IS1 and IS2 sampling currents exceed 200mA, consider replacing the compensation controller

2. Frequent Capacitor Switching

Symptom: Rapid and excessive capacitor bank switching.

Potential causes

Troubleshooting methods and precautions

Rapid load current fluctuations and inappropriately low delay time settings (less than 10s)

Increase delay time to a minimum of 30 seconds

Low target power factor

Adjust target power factor to more appropriate levels

Low reactive power threshold

Raise reactive power switching threshold

 

For a more direct look into the installation process and troubleshooting guide of the JKF8-12 Compensation Controller, check out our YouTube video:

Conclusion

Installing the JKF8-12 Intelligent LV Reactive Power Auto Compensation Controller requires precision and careful execution. By following these detailed steps, you’ll ensure optimal performance and reliability. At CHINT, we are committed to providing top-tier technological solutions. Our expert technical support team offers services to assist you throughout the installation process.

The Latest
JUNE 12, 2025 What Is Motor Start Up Current and Why Is It So High?

Discover why motor start-up current is so high and how it affects electrical systems. Learn how to protect motors effectively with CHINT's solutions.

JUNE 12, 2025 Selecting the Right Air Circuit Breaker for Data Centers and Critical Power Distribution

Discover how to select the right air circuit breaker for data centers. Learn about CHINT’s NA8 features, certifications, and smart integration benefits.

JUNE 11, 2025 Everything You Should Know About Solar Pumping System

Understand the benefits, applications, and components of solar pumping systems including CHINT’s NVFPV drives for reliable water access.

JUNE 10, 2025 How Altitude Affects the Performance of Moulded Case Circuit Breakers

Learn the effects of altitude on circuit breakers and explore CHINT’s NM8N-HV MCCB built for extreme conditions with high performance and safety.

JUNE 9, 2025 What Is A Pulse Relay and How Does It Work?

Explore the energy-efficient pulse relay technology used in automation, lighting, and security systems. Featuring CHINT’s NJMC1 relay for reliable performance.

JUNE 7, 2025 Understanding AC Contactors: Uses and Warning Signs of Failure

Learn how to recognize signs of a failing AC contactor and get expert tips on resolving issues, performing maintenance, and ensuring electrical safety.

JUNE 6, 2025 What Are Harmonics and Total Harmonic Distortion (THD) in Power Systems

Discover the causes, impacts, and solutions for harmonics and THD in electrical networks. Enhance reliability with CHINT’s NZB379 controller.

JUNE 6, 2025 Types of Lightning Surge Arresters and Their Functions

Discover the essential types of lightning surge arresters and their working principles. Learn how to protect your electrical systems from voltage surges effectively.

JUNE 5, 2025 Automatic Transfer Switch (ATS) Comprehensive Guide

Explore how ATS ensures uninterrupted power supply for critical applications. Learn about types, uses, performance, and CHINT solutions.

JUNE 5, 2025 Thermal Magnetic Circuit Breakers vs Hydraulic Magnetic Circuit Breakers

A comprehensive comparison of thermal magnetic and hydraulic magnetic circuit breakers. Learn about their protection, environmental susceptibility, trip time, size, and cost with CHINT.