Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN

Europe

Italy
Spain
Turkey
Kazakhstan
Netherlands
France

North America

Mexico

Latin America

Brazil
Peru
Ecuador
Utility PV & ESS

Choose your country & Language

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
Italy
Spain
Turkey
Kazakhstan
Netherlands
France
Mexico
Brazil
Peru
Ecuador

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

Can I Use General Miniature Circuit Breaker (MCB) for PV?

NOV 5, 2024

Can I Use a General Miniature Circuit Breaker (MCB) for PV?

Miniature circuit breakers are widely adopted. They are used for branch circuit protection in many electrical systems. However, as solar photovoltaic technology continues to expand rapidly, one question arises: Can I use a general miniature circuit breaker for PV? This article explores the answer to this question, highlighting the suitability of general miniature circuit breakers for PV, and recommended options that can reliably protect these types of electrical circuits.

 

Can I Use a General Miniature Circuit Breaker for PV or Not?

To answer this question, we need to understand the basic differences between alternating current (AC) and direct current (DC), and how they affect the operation of circuit breakers.

General MCBs are designed and rated based on specifications for AC circuits. AC power has a crucial characteristic that allows standard circuit breakers to function effectively: it periodically crosses through zero voltage points 50 or 60 times per second. This natural interruption in the current flow enables standard circuit breakers to safely interrupt the current without the risk of arcing.

However, DC current, as found in PV circuits, maintains a constant flow of electrons without zero crossings. This continuous flow presents a challenge for circuit breakers that are not designed for DC. To safely interrupt current, a circuit breaker must ensure there is enough time for the contacts to fully separate before the arc starts to re-ignite. This requirement leads to the need for larger magnetic motors and conductive components in DC circuit breakers compared to their AC counterparts.

 

The magnetic and conductive components in general-purpose miniature circuit breakers are not robust enough to handle DC current. They cannot reliably turn off the DC current within the breaker during a fault, which runs the risk of the breaker failing to trip or prematurely tripping. The inconsistency can potentially leave the system unprotected or cause damage to components over repeated stress.

Overall, general miniature circuit breakers are not suitable for use in PV systems due to their incompatibility with DC power. To ensure the safety and longevity of PV systems, it is essential to use circuit breakers that are specifically tailored for PV and other DC power systems.

Product Highlight: Ex9BP DC Miniature Circuit Breaker

CHINT is a manufacturer and supplier of electrical protection devices. For years, we have specialized in developing reliable circuit breakers for solar and other DC applications. Ex9BP DC Miniature Circuit Breaker is one of our top offerings in this category. Some key features of the Ex9BP DC miniature circuit breaker from the Noark series include:

  • Rated voltage of 500V DC for two-pole models and 1000V DC for four-pole models, covering a wide range of typical PV voltages.
  • Can reliably handle continuous current loads between 10-63 amps, enough capacity for most residential and commercial PV applications.
  • Certified per the stringent IEC/EN 60947-2, it offers a breaking capacity of 6kA.
  • Color coded contact position indicator provides a visual indication of the device status.
  • The product can realize non-polar wiring and ensure the safety of equipment reliably.
  • Specially designed for DC arc extinguishing chamber and arc striking angle design, perfect breaking DC arc.

Applications of Ex9BP

The Ex9BP DC MCB has applications in a variety of PV and other direct current installations. Some common scenarios of this advanced miniature circuit breaker include:

  • Residential and commercial rooftop PV arrays, providing protection for multiple solar modules wired in series into strings and combiner boxes.
  • Off-grid and hybrid solar homes, protecting batteries, inverters, and sensitive appliances that run on low-voltage DC power.
  • Industrial machinery, automating processes by protecting DC motors, conveyor systems, pumps, and factory installations.
  • Large-scale solar farms, safeguarding the high-current DC circuit and central inverters, optimizing energy generation, and maintaining grid stability.

Conclusion

Overall, while the general miniature circuit breaker performs well in AC applications, it is not suited for use in PV and other DC power systems. It’s recommended to use a reliable DC MCB for solar for that purpose. The Ex9BP from CHINT provides reliable overload and short-circuit protection tailored for direct current use. Visit our website to learn more about our full range of PV accessories, switchgear products, and custom solutions.

The Latest
JUNE 12, 2025 What Is Motor Start Up Current and Why Is It So High?

Discover why motor start-up current is so high and how it affects electrical systems. Learn how to protect motors effectively with CHINT's solutions.

JUNE 12, 2025 Selecting the Right Air Circuit Breaker for Data Centers and Critical Power Distribution

Discover how to select the right air circuit breaker for data centers. Learn about CHINT’s NA8 features, certifications, and smart integration benefits.

JUNE 11, 2025 Everything You Should Know About Solar Pumping System

Understand the benefits, applications, and components of solar pumping systems including CHINT’s NVFPV drives for reliable water access.

JUNE 10, 2025 How Altitude Affects the Performance of Moulded Case Circuit Breakers

Learn the effects of altitude on circuit breakers and explore CHINT’s NM8N-HV MCCB built for extreme conditions with high performance and safety.

JUNE 9, 2025 What Is A Pulse Relay and How Does It Work?

Explore the energy-efficient pulse relay technology used in automation, lighting, and security systems. Featuring CHINT’s NJMC1 relay for reliable performance.

JUNE 7, 2025 Understanding AC Contactors: Uses and Warning Signs of Failure

Learn how to recognize signs of a failing AC contactor and get expert tips on resolving issues, performing maintenance, and ensuring electrical safety.

JUNE 6, 2025 What Are Harmonics and Total Harmonic Distortion (THD) in Power Systems

Discover the causes, impacts, and solutions for harmonics and THD in electrical networks. Enhance reliability with CHINT’s NZB379 controller.

JUNE 6, 2025 Types of Lightning Surge Arresters and Their Functions

Discover the essential types of lightning surge arresters and their working principles. Learn how to protect your electrical systems from voltage surges effectively.

JUNE 5, 2025 Thermal Magnetic Circuit Breakers vs Hydraulic Magnetic Circuit Breakers

A comprehensive comparison of thermal magnetic and hydraulic magnetic circuit breakers. Learn about their protection, environmental susceptibility, trip time, size, and cost with CHINT.

JUNE 5, 2025 Automatic Transfer Switch (ATS) Comprehensive Guide

Explore how ATS ensures uninterrupted power supply for critical applications. Learn about types, uses, performance, and CHINT solutions.