Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam

Middle East & Africa

Saudi Arabia
South Africa
UAE
Egypt
Kenya

Europe

France
Italy
Spain
Turkey
Kazakhstan
Netherlands
United Kingdom

North America

Mexico
USA
Canada

Latin America

Brazil
Colombia
Ecuador
Peru

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam
Saudi Arabia
South Africa
UAE
Egypt
Kenya
France
Italy
Spain
Turkey
Kazakhstan
Netherlands
United Kingdom
Mexico
USA
Canada
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
chint
ZFW34A-252(H)
chint
ZFW34A-252(H)

ZFW34A-252(H)

252kV HGIS Product Feature

- Small in Size

To compare with AlS Substation, it can save 60 ~ 70% of the floor area, best way for saving current increasingly tense land

resources;

-Fast Installation

To transport the Comlieted bay. All HGIS components have been debugged and tested in the Factory. Only a few line connections

and routine tests are required on-site, therefore, the on-site installattion time of single bay can be ≤ 16h;

- Stability in Performance

The Circuit Breaker is the HGIS core component, which is horizontolly arranged, with low center of gravity, better stability and better seismic performance. It is especially suitable for earthquake prone areas (passed the AG5 test). The Circuit Breaker can be used in extremely harsh environments (Sandstorm, heavy pollution,etc.)

- Convenience in Replacemen

It is designed solely with anchor bolt fixing and overhead incoming andoutgoing lines, with independent bays, therefore, the

replacement of single bay can be carried out within 4h, also not be troubldas GIS Substation, which can be troubled by the long

power outage time caused by GIS Substation failure. The transformation arnd expansion of the Substation is simple and

convenient, especially suitable for the AlS Substation.

- Lower Life-cycle Costs

Refer to GIS and AlS, the HGIS has the multi features, such as minimum maintenance workload, minimum construction difficulty

shortest construction time, minimum overhaul difficulty, lower equipment operation cost and shorter construction period

for reconstruction and expansion.

Product Information

Recommend Blogs
FEBRUARY 14, 2026 Designing with IEC 61439-Compliant Switchgear for Better LV Assembly Performance

Designing an IEC switchboard is necessary for every operation, whether industrial or commercial. Acquiring IEC 61439 design verification for MDBs is important.

FEBRUARY 12, 2026 Selecting the Right Control Components for High-Inrush Loads

Learn how to choose the proper control components like MCCB, overload relay, and contactors used in high inrush load for motor protection.

FEBRUARY 12, 2026 How Smart Meters Help Optimize Building Energy Use

Great building energy management makes use of smart meters to gauge energy consumption. Learn why smart metering is a sign of good energy monitoring practice.

SEPTEMBER 23, 2025 Manual Motor Starter: A Guide for Safer Motor Control

Every electric motor needs protection against fault conditions. In this article, learn how a manual motor starter helps you achieve this requirement.

AUGUST 1, 2025 Slim RCBO Solutions for Power Distribution: CHINT NB1L-20 for Compact, Compliant Installations

CHINT’s NB1L-20 is a great addition to any power distribution system. Learn why you should consider our product if you value safety and compliance.

JULY 14, 2025 UL Certification Requirements for OEMs: Essential Guide for Renewable Energy Projects in 2025

UL Certification Requirements for OEMs: Essential Guide for Renewable Energy Projects in 2025

JULY 10, 2025 Configuration Guide: Setting Up the CHINT SMG-WSR and SMG-ESR Open Protocol Gateway

Step-by-step protocol gateway setup guide for CHINT SMG-WSR and SMG-ESR, covering wiring, network configuration, and MQTT cloud connection.

JUNE 6, 2025 What Are Harmonics and Total Harmonic Distortion (THD) in Power Systems

Discover the causes, impacts, and solutions for harmonics and THD in electrical networks. Enhance reliability with CHINT’s NZB379 controller.

JUNE 6, 2025 Types of Lightning Surge Arresters and Their Functions

Discover the essential types of lightning surge arresters and their working principles. Learn how to protect your electrical systems from voltage surges effectively.

FEBRUARY 21, 2025 Key Differences Between Air Insulated Substations and Gas Insulated Substations

Common types of switchgear used in substations are AIS and GIS. This article will assess the primary difference between AIS and GIS substations for five critical aspects.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand