Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
Egypt
Kenya

Europe

France
Italy
Spain
Turkey
Kazakhstan
Netherlands

North America

Mexico
USA
Canada

Latin America

Brazil
Peru
Ecuador

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
Egypt
Kenya
France
Italy
Spain
Turkey
Kazakhstan
Netherlands
Mexico
USA
Canada
Brazil
Peru
Ecuador

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NWK1-GR-ILVRPACC-5
NWK1-GR-ILVRPACC-Front-1
NWK1-GR-ILVRPACC-Front-2
NWK1-GR-ILVRPACC-4
NWK1-GR-ILVRPACC-5
NWK1-GR-ILVRPACC-Front-1
NWK1-GR-ILVRPACC-Front-2
NWK1-GR-ILVRPACC-4

NWK1-GR

NWK1-GR series low voltage reactive power compensation controller adopts large dot matrix LCD screen and mobile

phone menu operation mode to realize man-machine exchange. Its sampling voltage range is AC (100~800) V and operating frequency range is (45~65) Hz, which are suitable for reactive power compensation and power distribution monitoring in different regions of the world.

ASIC chip is used to calculate and analyze the voltage and current collected through FFT (Fast Fourier Transform), so under a large harmonic component of power grid, the reactive power can be used as the basis of switching capacitors and combined with the power factor for switching. The capacitor capacity can be matched or switched in three phases or single phase by cycle, code or any combination of values to realize the optimal compensation effect. It is the newest smart reactive compensation controller introduced by our company.

The product integrates the functions of digital power grid measurement, record and storage, as well as Chinese and English or graphic real-time display of dozens of electricity, with high power measurement accuracy under harmonic environment. Besides, it provides power quality analysis, harmonic value protection and RS485 communication transmission function.

Applicable standards: JB/T9663-2013; DL/T597-1996.

Product Information

Recommend Blogs
MARCH 10, 2026 How Surge Protective Devices (SPDs) Keep Your Small Business Equipment Safe

Learn how surge protection and electrical protection strategies support small business power needs, reduce downtime, and keep equipment reliable as demand grows.

MARCH 9, 2026 Maintaining Electrical Safety Across Distributed Infrastructure

Learn how smart maintenance strategies protect electrical safety across distributed facilities, reducing downtime and keeping multi-site operations predictable and reliable.

MARCH 8, 2026 How Automated Distribution Systems Improve Network Stability

Grid automation allows for better management of distribution systems and your network. See how automated distribution systems improve outage management.

MARCH 7, 2026 Why Certification Matters in High-Voltage Equipment

Learn why IEC standards and electrical safety certification matter for high-voltage equipment, improving reliability, protection accuracy, and risk control across power networks.

MARCH 6, 2026 Ensuring Continuous Power Supply in Critical Infrastructure Like Airports

Ensure reliable airport power with robust critical power systems and layered resilience. Explore how redundancy, monitoring, and design keep aviation operations running smoothly.

FEBRUARY 14, 2026 Designing with IEC 61439-Compliant Switchgear for Better LV Assembly Performance

Designing an IEC switchboard is necessary for every operation, whether industrial or commercial. Acquiring IEC 61439 design verification for MDBs is important.

FEBRUARY 12, 2026 Selecting the Right Control Components for High-Inrush Loads

Learn how to choose the proper control components like MCCB, overload relay, and contactors used in high inrush load for motor protection.

FEBRUARY 12, 2026 How Smart Meters Help Optimize Building Energy Use

Great building energy management makes use of smart meters to gauge energy consumption. Learn why smart metering is a sign of good energy monitoring practice.

OCTOBER 15, 2025 Guide to MCB Trip Curves: Selecting the Right B, C, or D Curve for Overcurrent Protection

Solve nuisance tripping problems for good. Our guide helps you diagnose why your breaker trips on startup and shows how to select the correct B, C, or D curve for motors, pumps, and other loads.

SEPTEMBER 28, 2025 Industrial Diesel Generator Safety Devices That Keep Operations Running

Discover how diesel generator safety devices like MCCBs, ACBs, and relays ensure reliable backup power, protect facilities, and keep operations running safely.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand