Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
JSS48A Time Delay Relay
JSS48A Time Delay Relay
JSS48A Time Delay Relay

JSS48A Time Delay Relay

The CHINT JSS48A Time Delay Relay is a versatile and reliable timing device used in control circuits for connecting or disconnecting loads at preset intervals. Supporting AC up to 380V and DC up to 240V, it provides multiple time ranges and configurable delay units for precise automation control. Available in panel, DIN-rail, and plug-in mounting types, the JSS48A is ideal for applications in industrial machinery, automation systems, and power control panels, meeting IEC 60947-5-1 standards.

Product Information

Recommend Blogs
APRIL 15, 2026 Why MCCBs Are Critical for Industrial Safety and Compliance at High Voltage Levels

A fuse box upgrade is essential to ensure that your consumer unit can keep up with your current power demand and electric safety needs. Learn more in this article.

APRIL 14, 2026 Creating Energy-Efficient Electrical Installations

Learn how final distribution boards, smart meters, and proper electrical installation design work together to create energy-efficient homes that reduce power waste.

APRIL 14, 2026 RCCB Tripping Explained: Causes, Nuisance Tripping, and Electrical Fault Diagnosis

In this article, we explain the role of RCCB tripping in electrical safety and what causes unintended or nuisance tripping.

APRIL 14, 2026 Why OEMs Are Standardizing on Modular Breaker Platforms

Learn why OEMs adopt modular circuit breaker platforms to cut engineering time, boost design flexibility, and streamline industrial projects.

APRIL 14, 2026 Selecting the Appropriate Circuit Breaker for Residential and Industrial Applications

Proper circuit breaker selection entails understanding of circuit breaker types and important selection factors to consider. Learn more in this article.

APRIL 14, 2026 Why Modular Electrical Solutions Offer Faster ROI

Discover how modular electrical systems and prefabricated LV/MV solutions deliver faster ROI through reduced timelines and predictable costs.

APRIL 14, 2026 How to Plan a Fuse Box Upgrade: Costs, MCB Installation, and Safety Benefits

A fuse box upgrade is essential to ensure that your consumer unit can keep up with your current power demand and electric safety needs. Learn more in this article.

APRIL 13, 2026 Common Wiring Mistakes That Reduce Safety in Homes

How do hidden home wiring mistakes impact safety, and why electrical compliance matter? Learn how correct MCB selection reduces risk in modern homes and long-term reliability.

APRIL 13, 2026 How to Install and Use Your Home EV Charger Safely

Learn how to safely manage home charging with expert tips on EV charger installation, daily use, and protective measures for reliable, stress-free charging.

MARCH 10, 2026 How Surge Protective Devices (SPDs) Keep Your Small Business Equipment Safe

Learn how surge protection and electrical protection strategies support small business power needs, reduce downtime, and keep equipment reliable as demand grows.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the main function of the JSS48A Time Delay Relay?

It’s used to control the connection or disconnection of circuits after a preset delay, enabling precise timing control in automation systems.

 

What voltage options are available?

The JSS48A supports a wide range — AC 12V to 380V and DC 12V to 240V, making it adaptable for global applications.

 

How accurate is the JSS48A relay?

It provides ±0.05 s accuracy for short delays and ±1% for longer settings, ensuring reliable timing consistency.

 

What are the available time ranges?

You can select from 0.01 seconds up to 9999 minutes, with multiple adjustable ranges and time units.

 

How can it be installed?

It supports panel mounting, DIN-rail, or plug-in bases (CZS08C/CZF11A-E) for flexible integration in control panels.