Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

How Does a Soft Starter Work - Working Principles and Applications

SEP 3, 2022

soft starter working principles applications
soft starter working principles applications
soft-starter-working-principles-applications

Table of Contents

  1. Motor Starter Methods
  2. How Does a Soft Starter Work?
  3. How do soft starters guarantee voltage control?
  4. Soft Starter Applications
  5. CHINT Soft Starters
  6. Wrapping Up

soft starter or motor soft starter is a control device for electric motors that allows starting and stopping in a smooth and controlled manner.

Unlike full voltage starters, soft starters manage the voltage and supply it gradually, protecting the motor while optimizing time and resources by reducing maintenance due to wear.

Learn about their working principles and how they can help you improve the features of your machines.

Motor Starter Methods

Before learning how soft starters work, it is important to understand the three basic types of technologies used in these devices, or in other words, the three basic methods of starting a motor.

Direct-on-line (DOL)

These devices transmit full load current to the motor as soon as the ignition command is given. They are usually used in basic motors.

Soft starters

These starters apply voltage, current and torque smoothly and gradually to provide greater control at starting and stopping, thus giving the motor advanced mechanical and electrical features.

Variable frequency drivers (VFDs)

Also known as autotransformer starters, these devices automatically convert AC line voltage to DC voltage and vice versa to control a motor’s starting, running time, and stopping phases.

How Does a Soft Starter Work?

3-phase induction motors need a fairly high current load to start (between 3 and 15 times the nominal current), something that can end up damaging the motor and other components in the long term.

Basically, soft starters allow the voltage to be controlled more effectively by supplying the current gradually until it reaches the nominal current required by the motor to run at its maximum speed.

The key to achieving this is the use of certain components that allow the current flow to be controlled gradually in the different phases, usually a series of silicon controlled rectifiers (SCR), or thyristors.

These SCRs function as “gates” that open (ON) and close (OFF) as the motor speeds up. This allows the voltage supplied to the motor to be controlled with great efficiency.

How do soft starters guarantee voltage control?

First of all, a motor soft starter is basically made up of two components:

Power circuit

Through this circuit circulates the current that is supplied to the motor. This consists of a series of thyristors and some protections and current transformers.

Control circuit

This is the circuit in charge of controlling, monitoring and protecting the components of the power supply circuit, in addition to the user interface circuits that can be configured according to each application.

When a gate pulse (firing pulse) is applied to a set of thyristors, they open (ON) and allow current to flow to energize the motor in the corresponding phase. The angle of each pulse is what determines how much current can pass and for how long.

This ability of the thyristors to control the variation of the firing angle makes it possible to generate an effective voltage at the output that increases gradually and continuously until it reaches the nominal voltage of the network.

Both the angle of the firing pulse and the duration of the current flow are controlled by the user through the control circuitry by setting certain parameters to limit current flow. In this way is how soft starters:

  1. Control the operability of motors, especially the starting and stopping phases
  2. Protect motors and controllers from high voltages and excessive heat

Soft Starter Applications

There are many types of motors that can greatly benefit from the use of soft starters, some more than others.

However, the need to install a starter on a motor will depend on the characteristics of such a motor and its susceptibility to damage by receiving current and heat in excessive amounts during the starting phase.

Here are some of the most common applications.

Fans

Fans are often kept operational for long periods of time, but can also greatly benefit from a smooth, progressive starting phase to help extend their lifespan. This is especially important when the correct operation of a fan is key to preserving food or delicate pieces.

Water/liquid pumps

These types of pumps are often damaged due to the strong pressure that builds up in the pipes during starting and stopping. Soft starters can significantly reduce the risk of damage by allowing a controlled increase in pressure.

Belts

A sudden, rough start can put undue stress on conveyor or transmission belts and cause them to break or slip out of their guides. A smooth start can ensure that the straps stay in place and last longer, as well as protect the items being carried and other pieces.

Electric rotors

Motors such as those used by electric helicopters need soft starters to reduce the great danger of sudden starting or stopping of their rotors.

chint njr2 d series soft starter
chint njr2 d series soft starter
chint njr2 d-series-soft-starter

CHINT Soft Starters

CHINT soft starters have advanced technology to provide high-precision control over SCR modules and enable extremely soft starting and stopping phases on 3-phase AC induction motors.

These powerful soft starters also provide a series of additional protection features to ensure longer life in different machines in a wide variety of applications in different industries.

NJR2-D Series Soft-Starter

The NJR2-D series is designed for applications where torque requirements are not too high.

This 3-phase asynchronous motor starter finds applications for fan, pump, compressor, ball mill, and crusher motors, among others. This allows it to find applications in fields as diverse as metallurgy, petroleum, fire, mining, water supply, municipal, food, cement, petrochemical, etc.

The starter has additional protection features including:

  • Overload
  • Input phase failure
  • Output phase failure
  • Load short-circuit
  • Starting limiting overtime
  • Over-voltage
  • Under-voltage

A lightweight device with a wide variety of applications, good load adaptability, and high reliability. 

NJR2-ZX On-line Soft-Starter

The NJR2-ZX series belongs to the category of reduced voltage starters, ideal for applications where a lot of torque is not required.

The starter allows precise control over the starting and stopping phases in 3-phase AC induction motors (squirrel cage type), but without requiring the use of a bypass contactor.

The device offers protection functions such as:

  • Overload
  • Input phase failure
  • Output phase failure
  • Load short-circuit
  • Starting limiting overtime
  • Over-voltage
  • Under-voltage

Like the previous model, this starter finds ample use in electrically driven equipment in a wide variety of industries and is a new step in improving similar traditional devices. 

Wrapping Up

Soft starters are control and protection devices that can significantly reduce the chances of malfunctioning of motors and various machinery by protecting them from sudden voltage surges and overheating, thus helping to significantly increase the lifespan of these devices.

CHINT soft starters have been designed for flexibility and scalability, as well as offering additional built-in features and functions that will allow you to reduce your energy and maintenance costs. Find out the high-quality products that CHINT can offer you here.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.