Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

Residual Current Device (RCD) Explained

JUN 16, 2023

Table of Contents

  1. What is a Residual Current Device (RCD)?
  2. What are the Main Types of RCD?
  3. What is the Sensitivity of RCDs?
  4. Are There Limitations to RCDs?
  5. How Do You Test RCDs?
  6. Conclusion

residual current device, known as an RCD, is a personal safety device instituted in electrical systems. It works to switch off electrical current whenever there is a fault detected. RCDs are considered personal protection devices because they work to protect humans from electrical shock and greatly reduce the risk of an electrical fire.

What is a Residual Current Device (RCD)?

This electrical device is specifically constructed to switch off the flow of electrical current whenever a ground leak is detected at a significant level that can be dangerous to humans. RCDs are able to switch the current flow within 10 to 50 milliseconds of detecting a prospective leak.

Each RCD will work to constantly monitor the electrical current flowing through one or more circuits. It actively focuses on measuring the live and neutral wires. When it detects that the electrical current flowing through both wires is not the same, the RCD will turn the circuit off. This indicates that the electrical current has an unintended path that is potentially dangerous, such as a person touching a live wire or an appliance that is acting faulty.

In most residential settings, these protection devices are used in wet rooms and for all appliances to keep homeowners safe. They’re also ideal for keeping commercial and industrial equipment safe from electrical overload that could potentially damage or even start an unwanted electrical fire.

What are the Main Types of RCD?

Since there are many different types of electrical devices that RCDs can be used for, there are many variations. We’re going to discuss the different variations below to give you a better understanding of the different RCDs that you may need, depending on the project that you’re working on.

Fixed RCDs

Fixed RCDs provide the highest level of protection and are installed in the fusebox. They’re designed to provide protection for groups of circuits or individual units. A fixed RCD will protect all of the sockets and wiring on a circuit and all the connected appliances to that circuit.

Socket-Outlet RCDs

This unit replaces a standard socket outlet. It provides protection to anyone that comes into contact with the equipment plugged into the socket outlet and its leads. These are great for both fire and electrocution protection when using appliances.

Portable RCDs

Portable RCDs provide similar protection to the socket outlet RCD. This unit is useful when you don’t have a fixed or socket outlet RCD. You simply plug the portable RCD into the socket outlet and enjoy protection for any person that comes into contact with the equipment, its leads, or anything plugged into it.

Switchboard Mounted RCDs

This type of RCD is non-portable and is specifically installed at the switchboard level. It works to provide protection for a selected circuit or the complete installation.

What is the Sensitivity of RCDs?

The most imperative part of any great RCD is its sensitivity. This is how quickly it senses and responds to a current leakage by disconnecting the circuit or circuits. All RCDs are designed to automatically switch off the circuit before it causes damage or injury. Different devices will have different RCD sensitivity levels.

Typically, these fall into three categories, which are low, medium, and high. Low RCDs are best for protecting small circuits, while high RCDs are better for protecting larger circuits for heavy-duty appliances and industrial machinery. All sensitivities are measured in milliamperes, or mA for short.

Low RCDs are designed for industrial applications and trip at residual currents above 500mA. Medium RCDs trip between 100 and 300 mA and are usually found in commercial buildings like stores and offices. Lastly, the high-sensitivity RCDs trip at 10 mA to 30 mA and are found mainly in residential settings.

Are There Limitations to RCDs?

As with all devices, the residual current device RCD will have some limitations that you need to be aware of. One known limitation is that the RCD will not turn off a circuit if a human comes into contact with the active and neutral conductors. This is because there is no leakage in the electrical current as it flows through the human body. The RCD will only detect a leak when the current flows to the earth.

RCDs are known not to detect overload conditions on phase-to-phase short circuits and phase-to-neutral short circuits.

How Do You Test RCDs?

The integrity of an RCD should be tested on a regular basis. All sockets and fixed RCD should be tested about every three months. Portable units should be tested each time you use them. Testing helps to ensure that your RCDs are working efficiently and will protect you from any potential electrical hazards.

The process of testing an RCD is fairly straightforward. You want to hit the test button on the front of the device. When you release it, the button should disconnect the energy current from the circuit.

Hitting the button simply stimulates the earth’s leakage fault. To turn the circuit back on, you’ll need to turn the on/off switch back to the on position. If the circuit doesn’t turn off, then there’s an issue with your RCD. It’s best to consult a licensed electrician before using the circuit or appliance again.

Conclusion

RCDs are a great device to help protect humans from potential electrocution and prevent electrical fires when there is a ground leak in the electrical current flow. Chint Global has various RCD products that will help to keep your home, business, and products safe for all.

FAQ about Residual Current Device

Are RCDs the same as circuit breakers?

What causes a RCD to trip?

What to do if RCD keeps tripping?

Are RCDs suitable for all electrical appliances and devices?

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.