Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

Dry Type Transformer VS Oil Filled Transformer

MAY 27, 2022

CHINT-110kV-power-transformer-1536x913-20220527
CHINT-110kV-power-transformer-1536x913-20220527
CHINT-110kV-power-transformer-1536x913-20220527

Table of Contents

  1. What is a Dry-Type Transformer?
  2. What is an Oil-Filled Transformer?
  3. Dry-Type Transformers vs. Oil-Filled Transformers: Key Differences
  4. CHINT Dry-Type and Oil-Filled Transformer
  5. Final Wordings

Dry-type transformer vs. oil-filled transformer is the most common debate in the market today. If you, too, are confused about whether to go for dry-type transformers or oil-filled transformers, then read this article till the end!

This post is the ultimate guide for people confused about how they differ from each other.

Transformers are becoming increasingly popular for altering the voltage in conventional power circuits. Whether you want to reduce the voltage to operate low-powered devices or raise the voltage to allow for long-distance electric power transmission, transformers are the way to go!

There are two types of transformers: dry-type transformers and oil-filled transformers. Even though they have the same objective, these transformers differ significantly. These distinctions are significant enough that the different transformer types are better suited to specific applications.

This article highlights the differences between dry-type transformers and oil-filled transformers. You will distinguish between their cost, maintenance, noise, energy efficiency, etc. So, let’s get started, shall we!

What is a Dry-Type Transformer?

A dry-type transformer is a motionless piece of equipment that uses environmentally acceptable temperature insulation systems. They are also known as “cast resin type transformers.”

The transformer is housed in a case with adequate ventilation, which results in the coils being cooled by the air inside the case. Additionally, they include varnished copper or aluminum windings. Because of the cooling constraints, dry-type transformers’ maximum voltage is restricted to 35kV.

Types of Dry-Type Transformers

The global market for dry-type transformers is estimated to increase at a CAGR of 6.1 percent from 2020 to 2027 due to increasing advancements in the types of dry-type transformers. There are several different types of dry-type transformers on the market, including:

  • Vacuum Pressure Impregnated (VPI) Transformers
  • Vacuum Pressure Encapsulated (VPE) Transformers
  • Open Wound Transformers
  • Cast Coil Transformers

Dry-type transformers have a wide range of commercial, industrial, and utility applications. They are commonly utilized in small and medium-voltage applications in electric equipment.

What is an Oil-Filled Transformer?

Oil-filled or oil-immersed transformers are voltage conversion devices that use oil to keep the transformer cool. This type of transformer structure is mounted in a welded steel oil tank filled with oil.

When an oil-immersed transformer is in use, the heat generated by the coil and iron core is first transferred to the insulating oil, then to the cooling fluid. Due to the liquid’s inflammability, oil-filled transformers are mostly used in outdoor installations.

Types of Oil-Filled Transformers

The oil-filled transformer industry exceeded $28.3 billion in 2020. The market is expected to grow at about 3.5% between 2021 and 2027. There are two main types of oil-filled transformers:

  • 1-Phase Transformers
  • 3-Phase Transformers

Oil-type transformers can be put on the ground, on a pad, or on a pole. They function well in various environments, including transmission and distribution lines, renewable energy generation, and small businesses.

220kV-Power-Transformer-1-20220527
220kV-Power-Transformer-1-20220527
220kV-Power-Transformer-1-20220527

Dry-Type Transformers vs. Oil-Filled Transformers: Key Differences

Take a look at the differences between dry-type and oil-filled transformers to understand how they perform.

1- Cooling Medium

Transformers overheat under load. They need a cooling medium to prevent overheating and potentially causing a fire or explosion.

The most significant distinction between the two transformers is their cooling medium. Dry-type transformers employ air as a cooling medium, while oil-filled ones, as the name suggests, use oil.

2- Maintenance

Oil-filled transformers are more high maintenance than dry-type ones. Oil-filled transformers require additional attention because the oil must be tested for chemical contamination regularly. Additionally, they require oil filtration at least once a year.

Dry-Type Transformers, on the other hand, are chemically resistant. Even if a minor event occurs, they do not need to be disconnected from the grid.

3- Operational Cost

You might assume that oil-filled transformers entail higher costs than the dry types. However, the reality is the contrary.

Oil-filled transformers are less expensive because they use conventional energy efficiency, making them dependable and long-lasting. Dry transformers use more energy and entail a higher operational cost.

4- Recyclability

Dry-type transformers have a restricted coil recycling at the end of their service life, whereas oil units have a much easier core recycling.

5- Efficiency

Oil-filled transformers are more efficient than dry-type transformers, which are larger and have a lower voltage rating. Thus, the dry types are more prone to overheating during overload, resulting in higher electrical losses and maintenance costs.

6- Location

This is arguably the most significant consideration when choosing a transformer and a major difference between the two. Oil-filled transformers are typically installed outdoors due to the risk of an oil spill, which could pose a serious threat.

Dry-type transformers are specifically utilized in buildings since they are less hazardous and safer for the environment. They’re also less explosive, so they’re utilized in malls, offices, hospitals, etc.

Amorphous-Alloy-Core-Dry-type-Transformer-20220527
Amorphous-Alloy-Core-Dry-type-Transformer-20220527
Amorphous-Alloy-Core-Dry-type-Transformer-20220527

CHINT Dry-Type and Oil-Filled Transformer

Although these distinctions are widely regarded as general guidelines, there is always room for exceptions. Many of the world’s largest transformer manufacturers, like CHINT Global, are making significant technological advancements.

If you are confused about which brand to go for, take a look at these best-selling CHINT dry-type and oil-filled transformers:

Amorphous Alloy Core Dry-Type Transformer

This dry-type transformer is formed of amorphous alloy ribbon, an innovative type of energy-saving semiconductor. The ribbon comprises iron, silicon, boron, carbon, and other compounds.

Amorphous alloy core provides high saturation magnetic induction, high resistivity, minimal loss, and other advantages over standard magnetic materials.

The CHINT amorphous alloy core dry-type transformer is good for volatile and explosive environments. It is ideal for high-rise buildings, shopping plazas, airports, subways, railway stations, and industrial sectors.

Features:

  • Lower operating noise
  • Short-circuit resistant
  • Excellent thermal performance
  • Excellent moisture, fire, and explosive resistance
  • Compact and lightweight

220kV Power Transformer

The CHINT 220kV Power Transformer has a large capacity. Thus, it will save a significant amount of electrical energy, prevent power loss, conserve energy sources, and lower user expenses.

It features a magnetic core, windings, and brushings. Their coils and core are submerged in oil, cooling and insulating them. Convection transports oil via ducts in the coils and around the core assembly.

The CHINT 220Kv Power Transformer is ideal for power plants, power stations, and large-scale industrial applications.

Features:

  • High operational security and dependability
  • Cost-effective
  • Great insulation capabilities
  • Compact and lightweight
  • Low noise generation
  • Fast delivery

Final Wordings

Based on our dry-type transformer vs. oil-filled transformer analysis, oil-filled transformers appear to be a better alternative in terms of energy-saving, cost-saving, and recyclability. Dry-type transformers, on the other hand, are safer for interior operations.

Whether you’re looking for an oil-filled or dry-type transformer, you should always deal with a trusted provider that offers the finest items on the market CHINT dry-type transformers, and oil-filled transformers are the finest choice in this case. With CHINT, you are sure to receive top-quality equipment at reasonable rates!

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.