Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

What Is A DIN Rail? Basics and Different Types | CHINT Blog

DEC 20, 2022

Table of Contents

  1. What Is A DIN Rail?
  2. Why Are DIN Rails Important?
  3. Din Rail History
  4. Types Of DIN Rails
  5. CHINT Modular DIN Rail Products
  6. Conclusion

Still widely underrated, DIN rails play a pivotal role in structural and mechanical support when dealing with standardized cabinet mounting in small, mid, and large-size electrical installation projects. Their main objective is to provide a unified international standard in measurements and components that can remain independent from manufacturers, regardless of time and place.

What Is A DIN Rail?

DIN rails are relatively simple to grasp; they’re long metal strips that allow you to attach different pieces of electrical hardware to cabinet racks. Of the many kinds of electrical equipment, most fall into the control group category, such as meters, circuit breakers, terminal blocks, solenoids, actuators, power supplies, electrical relays, motor controllers, and programmable logic controllers.

DIN rails can either go directly onto the wall or within the interior panel of electrical enclosures. In the first scenario, you can attach all electrical components directly onto the rail or use another electrical partition. In the second scenario, all pieces of equipment go straight onto the rail.

Why Are DIN Rails Important?

DIN rails offer several advantages to an electrical installation. First and foremost, we must speak about standardization. DIN rails allow you to choose from a wide selection of components and manufacturers to seamlessly install these pieces of hardware into the panels, regardless of project size or geolocation.

This feature of cross-sectional availability provides you with the flexibility and creativity to design your customized electrical solutions without compromising the integrity and functionality of the project. Other noteworthy benefits of using DIN rails on your installations include:

  • Smooth installation: when working with non-DIN panels, sometimes you have to dismantle the entire structure to fit additional hardware. DIN rails ensure that all new components slide or snap right into position.
  • Space optimization: as part of the much-mentioned standards, DIN rails provide an easy installation even in the tightest spaces, providing a convenient way of connecting internal and external wirings.
  • Cost-effectiveness: less effort and less utilized space translate into a money-saving project, reducing downtimes and leaving you with extra time to perform other duties.
  • Organized layout: DIN rails provide an aesthetical and pleasant arrangement that allows for a well-structured map to facilitate maintenance access and overall safety.

Din Rail History

DIN stands for Deutsche Institut für Normung, which from German translates as German Institute for Standards in English. The rack-mounting system that we now so commonly see in several industries in the market was born in Germany in the late ’20s. But, it wasn’t until the early ’50s that it became more widely accepted and readily available, domestically and internationally.

The original DIN standards were born in 1928 at the hands of a company called Rheinisch-Westfälisches Elektrizitätswerk (Rhenish-Westphalian Power Station), a company that still exists to this day. In the 1900s, there were no standards whatsoever for electrical panel development. People built them using whatever components they could find in whichever way they saw fit.

RWE saw this problem and turned it into an opportunity, devising what we know today as the G-rail. Initially built from porcelain, these rails attached a metal bus bar running along its center. Eventually, manufacturers realized that porcelain was too fragile to serve its purpose, and metal rails became the new trend.

In the ’50s, DIN acquired the original designs by RWE and further developed the standardization process of these rails. In the USA, NEMA (National Electrical Manufacturers Association) also adopted the normative standards, and, ever since, virtually all electrical control hardware components have been complying with DIN standards.

Types Of DIN Rails

Top Hat Rails

Also known as TS35, the Top Hat Din Rails are the most common, most readily available, and most versatile rails according to the DIN industry standards. The name refers to the fact that its cross-section resembles a deep hat (basically, a rectangular bowl), and the number indicates these rails are 35mm wide. The standard channel depth is 7.5mm, but a 15mm (deep hat) channel depth is also available.

Mini Top Hat Rails

The TS15 is, by all means, a miniature version of the TS35. The two differences are the edge-to-edge measurement of only 15mm and the standard channel depth of 5.5mm. These rails are ideal if your available space is a premium or if you only need to attach compact components, such as relays or smaller junction boxes.

C-Rails

Once regarded as the industry standard (before the TS35 came along), these rails feature a 32mm edge-to-edge measurement and a C-shape cross-section. Due to its excellent wall support, this DIN rail is still widely preferred when mounting heavier components, such as transformers and power supplies.

G-Rails

Also known as TS32, these rails feature a deeper cavity on one of their extremities, resembling the letter G, measuring 32mm from edge to edge. This deeper channel usually goes at the lower edge of the panel, offering more robust support for those heavy-duty components. It also prevents unintentional backward installation.

DTSU666 Three Phase DIN Rail Meter
DTSU666 Three Phase DIN Rail Meter
DTSU666-Three-Phase-DIN-Rail-Meter

CHINT Modular DIN Rail Products

DTSU666 Three Phase DIN Rail Meter

This DIN rail meter is lightweight (400g) and compact (98x65x72mm), making it easy to install on all types of panels. It can accurately measure frequency, power factor, total kWh and kVarh, and instantaneous kW, kVar, Irms, and Vrms. With a low power consumption, at less than 1W, 5VA, it also includes the following specs:

  • Operating Range Limit: -40C to +75C
  • IP Rating: IP54 (protected from limited dust ingress and low-pressure water jets from any direction)
  • Operating Frequency: 50Hz or 60Hz

The DTSU666 Three Phase DIN-Rail Meter is ideal for accurately measuring the energy consumption at industrial factories, nautical ports, corporate buildings, large housing blocks, etc.

DDSU666 Single Phase DIN-Rail Meter

This DIN rail meter is even more lightweight (200g) and compact (98x65x36mm), making it ideal for panel installations with limited space. It can accurately measure power factor, frequency, total kWh, instantaneous kW, Irms, and Vrms. Also featuring a low power consumption (less than 1W, 5VA), this single-phase meter also includes the same specs as the three-phase model:

  • Operating Range Limit: -40C to +75C
  • IP Rating: IP54 (protected from limited dust ingress and low-pressure water jets from any direction)
  • Operating Frequency: 50Hz or 60Hz

The DDSU666 Single Phase DIN-Rail Meter is ideal for smaller projects that require only a single-phase connection, such as residential homes, small offices, storage units, etc.

Conclusion

Despite being underrated by some, DIN rails offer a crucial performance at all kinds of electrical installations. They save time, space, and money, all while ensuring that the project remains unified under international standards and easily upscalable for the future.

That, combined with chint top-notch meters for single-phase (DDSU666 Single Phase DIN-Rail Meter) and three-phase (DTSU666 Three Phase DIN-Rail Meter), there’s no project you can’t boost.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.