Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

What Is the Difference Between Current Transformer and Potential Transformer

AUG 3, 2021

chint-transformer-products-banner-20210803
chint-transformer-products-banner-20210803
chint-transformer-products-banner-20210803

Table of Contents

  1. What Is Current Transformer and Potential Transformer 
  2. Difference Between Current Transformers and Potential Transformers 
  3. Conclusion

The current transformer and potential transformer (also called voltage transformer) are both measuring devices. A CT lowers the current signals for measurement purposes, while a PT lowers high voltage values into lower ones. The transformers are designed to measure whether power systems are both accurate and safe.

In addition, the CT and PT transformer reduces the current and voltage from high to low value. The current transformer and voltage transformer have similar construction since they feature a magnetic circuit in their primary and secondary winding.

Regardless, they have distinct differences. This post breaks down the current transformer vs. potential transformer and highlights the differences between the two.

What Is Current Transformer and Potential Transformer

Current transformer

Also known as CTs, current transformers are devices that measure alternating current. They are widely used to measure high magnitude currents.

current transformer essentially lowers (steps down) a high current to a lower, safer level that you can manage properly. It steps down the current to be measured so that you can measure it with an average range ammeter.

Functions of a current transformer include:

  • Converting large primary currents into small 1A/5A current
  • Providing the current for the coil of measuring device and protective relaying
  • It separates primary voltage from secondary voltage.

Characteristics of a current transformer include:

  • The resistance of the instrument’s current coil with which the CT’s secondary winding is connected is small. The CT transformer operates under a state close to the short circuit under normal condition
  • The primary winding is installed in series in the current.

Potential Transformers

On the other hand, potential transformers, also known as voltage transformers, measure an aspect of the power supply. While a current transformer measures current, the potential transformer measures voltage.

The majority of American homes use different voltages for various purposes.

Functions of the potential (voltage) transformers include:

  • It measures and reduces high voltage values into lesser values
  • Voltage transformers proportionally convert the high voltage into a standard secondary voltage of 100V or lower for easier utilization of protective and measuring instruments/devices
  • To isolate the high voltage from electricians using the PT.
chint-client-referral-20210803
chint-client-referral-20210803
chint-client-referral-20210803

Difference Between Current Transformers and Potential Transformers

Function

One of the major differences between CT and PT transformers is their functions.

On the one hand, a current transformer reduces a high current to a safer and more manageable level that you can measure. It converts large primary currents into small 1A/5A currents that can be measured on the ammeter.

On the other hand, a potential (voltage transformer) measures and reduces high voltage values into lesser values. It converts the high voltage into a standard secondary voltage of 100V or lower.

Types

The current transformer is divided into two types, including wound and closed core. The potential transformer is also divided into two categories(types), including electromagnetic and capacitor voltage.

Connection

In the current transformer, the primary winding is connected in series to the transmission line whose current is to be measured, and full line current flows via the winding. On the other hand, the potential transformer is connected in parallel with the circuit, meaning full line voltage appears across the winding.

Transformation Ratio

The transformation ratio in a current transformer is high, while in the potential transformer, the ratio is low.

Primary and Secondary Winding

In a current transformer, the primary winding has a smaller number of turns and carries the current to be measured. In potential transformers, the primary winding has many turns and carries the voltage to be measured.

In a current transformer, the secondary winding possesses large numbers of turns on the secondary side and is connected to the current winding of the instrument. In a potential transformer, the secondary winding has a small number of turns on the secondary side and is connected to the meter or instrument.

Core

The current transformer is designed with silicon steel lamination, while a potential transformer is designed with top-quality steel operating at low flux densities.

Primary Current

In a current transformer, the primary current doesn’t depend upon secondary side circuit conditions. On the other hand, in the potential transformer, the primary current relies on secondary side circuit conditions.

Use

With a current transformer, you can use a 5 Ampere ammeter to measure high currents such as 200 amperes. On the other hand, with a potential transformer, you can use a 120V voltmeter to measure high voltages such as 11KV.

Secondary Side

In the current transformer, the secondary side cannot be open-circuited when under service. On the other hand, in a potential transformer, you can open-circuit the secondary side without any damage.

Input Value

In the current transformer, the input value is constant current, whereas, in a potential current, it is a constant voltage.

Secondary Winding Range

In a current transformer, the range is 1A or 5A, while in a potential transformer, it is 110V.

Burden

The current transformer doesn’t rely on the secondary burden, whereas the potential transformer depends on the secondary burden.

Applications

A current transformer has different applications, including measuring current and power, monitoring the power grid operation, and operating a protective overlay.

On the other hand, the potential transformer’s applications include power source, measurement, and operating protective overlay.

Generally, a current transformer’s secondary side allows a short circuit but no open circuit. On the other hand, a potential transformer’s secondary side allows an open circuit but no short circuit.

Conclusion

Ultimately, current transformer testing and potential transformer testing ensure that instrument transformers are working correctly. It also ensures voltage and current remain within their stipulated framework. The transformers ensure your electrical gadgets or home appliances are protected from sudden electrical problems.

Contact an electrical professional for more assistance and further information on the differences between current and voltage transformers.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.