Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

Difference Between Vacuum Circuit Breaker (VCB) and Air Circuit Breaker (ACB)

MAY 24, 2022

CHINT-NA1-A-Classic-Air-Circuit-Breaker-20220524
CHINT-NA1-A-Classic-Air-Circuit-Breaker-20220524
CHINT-NA1-A-Classic-Air-Circuit-Breaker-20220524

Table of Contents

  1. What is a Vacuum Circuit Breaker? 
  2. What is the Working Principle of VCB? 
  3. Why Do We Use Vacuum Circuit Breakers? 
  4. Difference Between Vacuum Circuit Breaker (VCB) and Air Circuit Breaker (ACB) 
  5. CHINT Circuit Breakers 
  6. The Bottom Line

Almost everyone has seen a circuit breaker in their homes or offices. And almost everyone knows how essential they are to protect against overloads, ground faults, and short circuits. But not everyone can tell whether it is a vacuum circuit breaker or an air circuit breaker. Yes, they are two different technologies!

If you, too, don’t know how to tell the two apart, this article has covered you covered! This post highlights the difference between vacuum circuit breakers (VCB) and air circuit breakers (ACB). Stay with us till the end, and you may also find our recommendations on the best VCBs and ACBs in the market. So, let’s get started, shall we?

What is a Vacuum Circuit Breaker?

As the name suggests, a vacuum circuit breaker is the type of circuit breaker that accomplishes arc quenching using a vacuum. The vacuum chamber, also known as the vacuum interrupter, is responsible for opening and closing current-carrying contacts.

Vacuum circuit breakers have a steel arch chamber located in the center. They are symmetrically built and stacked in ceramic insulators. The vacuum interrupter maintains a vacuum pressure between 10 to 6 bar.

The material used in the current that transports contacts can greatly impact how well the vacuum circuit breaker works. Top brands regard Cr/Cr as the ideal material employed in manufacturing vacuum circuit breakers.

The superior arc provides excellent insulating strength, making them ideal for medium and relatively high-voltage applications. However, they are not the finest choice for commercial purposes.

This is why VCBs are typically branded as high voltage indoor vacuum circuit breakers. Vacuum circuit breakers are ideal for systems requiring a voltage of 11 to 33 kV due to their low maintenance requirements.

Indoor-AC-High-Voltage-Vacuum-Circuit-Breaker-20220524
Indoor-AC-High-Voltage-Vacuum-Circuit-Breaker-20220524
Indoor-AC-High-Voltage-Vacuum-Circuit-Breaker-20220524

What is the Working Principle of VCB?

The arc in a vacuum circuit breaker forms when metal oils ionize in the contact. These contacts are separated when unexpected conditions occur or the arc becomes jammed in them.

The arc interruption that occurs inside vacuum breakers is different from the arc interruption that occurs inside other types of circuit breakers. The contacts release a vapor when they divide. These vapors comprise positive ions that are withdrawn from the contact’s surface.

The vapor will not stay if the current is reduced. This implies that the vapor density is determined by the current present in the arc. When the current reaches zero, the vapor density decreases, and the medium recovers its dielectric strength.

The arc will also have several parallel routes if the interfering current is minimal. The whole current will be split up into several parallel arcs. Furthermore, they will reject each other, causing them to expand across the contact surface. Vapors can release quickly if a high current value is established on the contact surface.

An essential property of a vacuum is that once an arc is produced inside it, it may be quickly extinguished due to the vacuum’s dielectric strength rapidly improving.

Why Do We Use Vacuum Circuit Breakers?

People use vacuum circuit breakers to regulate high voltage currents. They are ideal for demonstrating out-of-phase current dropouts and double-earth faults.

Vacuum circuit breakers are perfect for use in power stations and generators. People also use vacuum circuit breakers in railway applications because of their ability to switch traction current and electrical supply.

Moreover, these circuit breakers are found in circuit breakers with porcelain housing. Additionally, metal-clad switchgear also uses VCBs.

Difference Between Vacuum Circuit Breaker (VCB) and Air Circuit Breaker (ACB)

Both vacuum circuit breakers (VCB) and air circuit breakers (ACB) have valuable functions. However, they have numerous distinctions, listed below as follows:

1- Voltage Applications

Air circuit breakers are only used in applications where the voltage is less than 690 volts. These are commonly referred to as LT (low tension) applications. On the other hand, vacuum circuit breakers are ideal for medium voltage levels with voltages less than 33 kV.

2- Working Principle

The moving and stationary contacts are kept open air in a sealed package in an air circuit breaker. Thus, the arc is quenched by air every time the circuit breaker opens. Air circuit breakers are easily ionized because it contains less air, and air acts as the dielectric medium.

However, vacuum acts as the arc quenching medium in a VCB. The ability of a vacuum circuit breaker to break short circuits is pretty impressive since free electrons cannot exist in the presence of a vacuum.

3- Medium Pressure

Open-air pressure is sufficient to quench the arc in air circuit breakers. On the other hand, VCBs must maintain a vacuum pressure ranging from 10-2 to 10-6 torr.

4- Refilling

Because outside air is free of charge, ACB does not require manual refilling. On the other hand, there is no way to replenish the vacuum in a VCB automatically. You must replace the vacuum container if it stops functioning.

5- Application

Air circuit breakers are frequently utilized in the LT MCC, the secondary feeder circuit of the power transformer, and the LT PCC. They are ideal for indoor use; you cannot use them outside.

On the other hand, Vacuum circuit breakers are used to start motors with higher horsepower.

6- Arc Chute and Arc Development

In air circuit breakers, arc chutes are used to prevent arc formation. It divides the arc into smaller sections. Without an arc chute, ACB cannot function. Arc development is high in ACBs.

Conversely, arc chutes are not required by VCB. Additionally, vacuum circuit breakers have less arc development because there is nothing to ionize other than contact substance.

NA1-Air-Circuit-Breaker-20220524
NA1-Air-Circuit-Breaker-20220524
NA1-Air-Circuit-Breaker-20220524

CHINT Circuit Breakers

As promised, here is our top recommendation on the best circuit breakers in the market:

1- NXV-12 Indoor AC High Voltage Vacuum Circuit Breaker

The NXV-12 Indoor AC High Voltage Vacuum Circuit Breaker fulfills the needs of both electric and manual operation. It is fitted with a low-power modular spring operating mechanism.

The closing operation is completed after getting the closing signal or pushing the closing button by hand; when the closing action is done, the opening operation is performed after receiving the opening signal or pressing the opening button by hand.

Features:

  1. Durable and reliable
  2. Use environmental protection electrical plastic
  3. Easily recyclable
  4. Perfect for industries, mining sector, power stations, and buildings

2- NA1 Air Circuit Breaker

The NA1 air circuit breaker is designed for AC 50Hz/60Hz circuits with rated service voltages of 400V and 690V and rated service currents of up to 6300A. Its primary function is to transmit electric energy and safeguard circuits and electric devices against over-load, under-voltage, short-circuit, and single-phase earthing faults.

Features:

  1. Reliable power supply
  2. Selective protective functions
  3. Suitable for power stations, factories, mines, and high-rise structures

The Bottom Line

Selecting the right circuit breaker gets easy once you know the proper details. After that, you just need to select a brand and order your VCB or ACB. For those hesitant to choose a brand for their vacuum circuit breaker or air circuit breaker, we suggest CHINT. The company guarantees high-quality products at competitive rates and offers fast delivery!

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.