Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

Miniature Circuit Breaker: Working and Application

SEP 9, 2023

Table of Contents

  1. What is Inside a Miniature Circuit Breaker?
  2. Working Principle of MCB
  3. MCB Compared to Other Circuit Breakers
  4. Miniature Circuit Breaker: Operation
  5. How to Select Proper MCB for Different Loads
  6. Conclusion

Miniature circuit breakers are small but mighty safety components that protect circuits from damage. They are crucial to safely and efficiently operate machinery and other electrical systems. Here’s a quick overview of how miniature circuit breakers work and their applications.

What is Inside a Miniature Circuit Breaker?

There are two basic components to a miniature circuit breaker. The first is a strip made of steel and copper, called the bimetallic strip. This is the strip that melts and interrupts the circuit in the case of a current overload. The other component is a coil that stops short circuits. The coil will trip in less than one-tenth of a second. The bimetallic strip responds quickly but slower than the coil.

Working Principle of MCB

The bimetallic strip is the chief protective component of an MCB. When an overcurrent flows through an MCB, the strip heats up. When it reaches the point of its rating, it melts and deforms. When that happens, it trips a latch.

That latch separates the contacts, stopping the current. After it trips, the only way to get the current flowing again is to replace the bimetallic strip manually and reset the MCB.

In the case of short circuits wherein there’s a surge in current, the MCB trips a solenoid connected to the latch. Like when the bimetallic strip melts, the tripped latch separates the contacts thereby preventing the flow of current.

This acts almost instantaneously to prevent any further damage. The solenoid generates a magnetic field when a high current passes through it and triggers the latch to release the contacts.

MCB Compared to Other Circuit Breakers

MCBs are great for certain jobs. Sometimes, though, they aren’t strong enough to protect bigger circuits. In commercial and industrial electrical systems, you might need different types of circuit breakers working together.

MCBs vs MCCBs

MCBs have ratings under 100 amperes while MCCBs can go as high as 2500 amperes. MCBs are used for low energy requirements such as residential use. MCCBs, on the other hand, are used for high power requirements for industrial and commercial use.

MCCBs also have a feature where they can be remotely turned off whereas MCBs don’t. That’s useful when a worker notices an issue that could cause damage to a particular circuit.

MCBs vs ELCBs

An earth-leaking circuit breaker detects current leakage, which is a kind of short circuit. An ELCB doesn’t detect overcurrent.

The ELCB reacts when current flows backward along the grounding wire. It’s an added protection against both circuits due to the current leakage and operator electrocution.

MCBs vs RCDs

RCDs (residual current circuit breakers) are designed to trip in as few as 25 milliseconds, four times faster than an MCB. They protect against faults with the ground that often result in fatal electrocution accidents. They generally trip when a ground fault of 25 or more milliamperes occurs.

Also, MCBs only respond to current that would become dangerous to the machinery. That might be dozens, or even hundreds, of times more powerful than what is dangerous for human beings.

Miniature Circuit Breaker: Operation

One of the most common reasons MCBs trip happens is when someone accidentally plugs two things, such as a microwave and desktop grill, into the same circuit and turns them both on at once. We’ve all gone down into the basement to flip the switch back into the “on” position at the junction box or to replace an MCB with a distorted bimetallic strip.

When the strip deforms, the spring that is attached to the latch moves, separating the contacts. When a short circuit happens, the magnetic field inside the coil causes a plunger to move, which then disengages the latch and the contacts. The force involved is called the magneto-motive force or MMF.

You can move a lever on the outside of the MCB to separate the contacts. If you choose to reset the MCB rather than replace it, then you can move the lever in the other direction once you add a new bimetallic strip or reset the spring and plunger.

When the contacts separate, there is a possibility of an electrical arc. The way circuits are built means that the arc is shunted through the runner into a selection of splitters to be safely quenched. Again, if resetting rather than replacing the MCB, once you complete all the reset steps, which include replacing faulty wires in the case of a short circuit, then you can turn the circuit back on because the MCB is ready.

How to Select Proper MCB for Different Loads

The first thing to determine is the load of the circuit that needs protecting. Then, you have to choose an MCB that has a rating equal to or slightly greater than that load. It can’t be too much greater than the load of the circuit because it would never trip. It can’t be too little, either, or it’ll trip all the time.

As an example, many junction boxes in homes are separated into 20-amp circuits. That means that the total amperage that any one of those particular circuits can carry is 20 amps. So, you can have one 20-amp appliance on the circuit, two 10-amp appliances, or an 8-amp and a 12-amp, etc.

Further, let’s say that a particular appliance has a 10-amp load. If the appliance itself has a circuit breaker, then it should be rated at greater than, or equal to, 10 amps and less than 20 amps. Ideally, it should be close to 10 amps. That way, the appliance can protect itself as well as rely on the main breaker at the junction box.

Conclusion

Choosing the right circuit breaker is important for the safety of the electrical circuits. Be sure to pick the right breaker for the right job. At Chint Global, we offer a wide range of miniature circuit breakers to suit various needs.

Whether you need a simple solution for your home or a robust system for your industrial setup, we have the right options for you. Explore our extensive range of circuit breakers and find the ideal solution for your electrical safety needs.

FAQ about Miniature Circuit Breaker

What are the types of MCBs?

Can an MCB protect against electric shocks?

Are there any safety precautions to consider with MCBs?

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.