Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

How to Read a Modular Contactor Nameplate (with Example)

JUN 3, 2024

How to Read a Modular Contactor Nameplate (with Example) 20240603 1
How to Read a Modular Contactor Nameplate (with Example) 20240603 1
How to Read a Modular Contactor Nameplate (with Example)-20240603-1

Table of Contents

  1. Understand the Circuits in a Modular Contactor
  2. Control Circuit
  3. Power Circuit
  4. How to Read the Nameplate of Modular Contactor
  5. What Else Should You Know about the NCH8-Z Modular Contactor
  6. Hum-Free Operation
  7. Compact Size
  8. Highly Applicable
  9. Conclusion

Modular contactors function as electromagnetic switches in electrical systems. They are often mounted on the rail of distribution panels and connected with other essential electrical devices to form a complete electrical setup. Thus it is important to ensure the contactor is compatible with other electrical devices and the entire electric system. This compatibility can be easily achieved by checking the nameplate of modular contactors. Read on to learn how to read a modular contactor nameplate correctly.

Understand the Circuits in a Modular Contactor

Before introducing how to read the nameplate of a modular contactor, it is crucial to clarify the circuits in a modular contactor first. There are two distinct circuits in a modular contactor:

Control Circuit

The control circuit in a modular contactor is responsible for powering the contactor itself. This circuit typically handles lower voltages and currents. When the control circuit is made, electrical current passes through the coil or electromagnet of the contactor, creating a magnetic field that induces a pulling force on the armature. This subsequently activates the power circuit.

Power Circuit

The power circuit is the high-current path that the contactor is designed to switch on and off. This is where the contactor’s primary function of making and breaking connections takes place. The power circuit is composed of heavy-duty contacts that are capable of handling high voltages and currents without welding or excessive wear.

How to Read the Nameplate of Modular Contactor

Let’s go through the common information on a modular contactor nameplate using the NCH8-Z Modular Contactor as an example:

How to Read a Modular Contactor Nameplate (with Example) 20240603 2
How to Read a Modular Contactor Nameplate (with Example) 20240603 2
How to Read a Modular Contactor Nameplate (with Example)-20240603-2
  • CHINT: This is the brand name of the contactor.

  • NCH8-63Z: This is the product name.

  • Ie 63A: This indicates that the rated operating current of the contactor is 63 amperes.

  • Ue~ 400V: The rated operating AC voltage is 400 volts, specifying the voltage level at which the contactor is designed to operate.

  • Ui~ 500V: The rated insulation AC voltage is 500 volts, which is a safety measure to protect against voltage surges.

  • AC-7a (AC-1) 63A: When applied to resistive (non-inductive) or slightly inductive loads, the contactor can handle a rated current of 63 amperes.

  • AC-7b (AC-3) 25A: When applied to high inductive loads, the contactor can handle a rated current of 25 amperes.

  • IEC/EN 61095 & IEC/EN 60947-4-1: These are certification numbers that indicate the contactor meets specific international safety and performance standards.

  • 230V AC: This indicates the control circuit can be powered by an alternating current of 230 volts.

  • 50/60Hz: This specifies the frequency of the AC power supply, which should be either 50 or 60 hertz.

  • 230V DC: This indicates the control circuit can also be powered by a direct current of 230 volts.

  • Wiring Diagram: A graphic provided that illustrates the connection points for both the control and power circuits. Terminals A1 and A2 refer to the control circuit, while terminals 1-8 refer to the power circuit.

What Else Should You Know about the NCH8-Z Modular Contactor

Reading and understanding the modular contactor nameplate ensures that you select the right contactor for your specific application. The NCH8-Z Modular Contactor from the top contactor company CHINT is highly recommended. Its advantages include:

Hum-Free Operation

The NCH8-Z Modular Contactor can eliminate noise up to 60 decibels. It is internally designed with unique silent coils and can create an absolutely quiet environment. This ensures quiet operation. It is ideal for environments where noise reduction is crucial, such as in offices, hospitals, hotels, etc.

Compact Size

The NCH8-Z Modular Contactor is of compact size. The 1P product is only 18 millimeters, and the 4P model can be as slim as 36 millimeters. This makes it ideal for installations where space is at a premium. Its modular design allows it to fit alongside MCB and SPD products in terminal boxes and small distribution boxes.

Highly Applicable

With a current rating of 16-63A and compatibility with both AC and DC, the NCH8-Z is suitable for all resistive and inductive loads. Customers won’t need to replace the contactor even if the electrical system changes from DC to AC.

Conclusion

Understanding the modular contactor’s nameplate is essential for the proper selection and application of these switches in your electrical systems. The NCH8-Z Modular Contactor stands out as a highly applicable product with hum-free operation and compact size. Visit our website for more about CHINT contactors.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.