Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Choose your country & Language

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

How to Install NXU-IIG Surge Arrester

FEB 14, 2025

Install NXU-IIG Surge Arrester
Install NXU-IIG Surge Arrester
Install NXU-IIG Surge Arrester

Table of Contents

  1. Pre-Installation Preparation
  2. Mounting the NXU-IIG Surge Arrester
  3. Wiring the Surge Arrester
  4. Post-Installation Checks and Maintenance
  5. Conclusion

The NXU-IIG Surge Arrester is a critical component for electrical systems. It protects them from various hazards. These include sudden voltage spikes and transient surges. These devices protect sensitive electronic equipment well. They offer protection from potential damage caused by unexpected electrical disturbances. This comprehensive guide provides a step-by-step approach to installing this surge arrester in a transformer safely and correctly.

Pre-Installation Preparation

Before starting, disconnect the power supply. The first step is to shut main the circuit breaker off. Wearing appropriate personal protective equipment is also recommended. These include insulating gloves and safety goggles. They offer effective protection against potential electrical hazards.

Necessary Tools

You’ll need a specific set of tools for successfully installing a surge arrester in the transformer. Gather these:

  • Wire strippers
  • Crimping tools
  • Wire lug
  • Flathead and electric screwdrivers
  • Multimeter
  • Torque screwdriver
  • Protective gloves and safety glasses

Lastly, carefully review the surge arrest product instructions. Verify the NXU-IIG model’s compatibility with your specific electrical system. Check the technical specifications to ensure you have the correct version for your application.

Mounting the NXU-IIG Surge Arrester

Mounting the surge arrester in transformer is a straightforward process. Following the manufacturer’s guidelines is key. Here are the steps:

  1. Align the upper end of the surge arrest device with the DIN rail’s top edge.
  2. Gently press down on the bottom edge.
  3. Ensure the bottom latch securely engages with the DIN rail.
  4. Confirm the arrester is firmly and evenly positioned.

If removal/dismantling becomes necessary, push upward on the bottom of the arrester, slightly lift the top, and carefully detach it from the DIN rail.

Wiring the Surge Arrester

Wire selection is critical for surge arresters. It depends on the product’s current rating. The following table provides guidance for wire selection based on different specifications:

Specification

Wire Type

Copper Cross-Sectional Area (mm²)

L and N Incoming Lines (20, 40 kA)

Power Lines

4

L and N Incoming Lines (60 kA)

Power Lines

6

L and N Incoming Lines (100 kA)

Power Lines

10

Ground Line (20, 40 kA)

Ground Wire

6

Ground Line (65 kA)

Ground Wire

10

Ground Line (100 kA)

Ground Wire

16

Next, prepare the wires. Carefully strip approximately 12 millimeters of insulation. Use crimping pliers to attach wire lugs. Make sure they are attached securely. When connecting, use a high-quality torque screwdriver. Set the torque value to 2.0 N.m. This will ensure a stable connection.

It’s recommended to always follow the electrical wiring diagram and comply with local electrical regulations during installation. This will ensure safe, optimal, and successful installation.

Post-Installation Checks and Maintenance

Environmental conditions play a crucial role in the NXU-IIG Surge Arrester’s performance. Check the ambient temperature within the manufacturer’s range. Monitor humidity levels too. Also, evaluate the area for potential corrosive elements like industrial chemicals, salt air, or excessive dust. These might compromise the arrester’s functionality.

The degradation indication window serves as the health indicator of surge arresters. When the window turns red, it signals the protection module has reached the end of its effective life. This color change indicates significant internal wear that compromises the arrester’s protective capabilities. Immediate replacement is essential to maintain your equipment’s safety.

Conduct routine checks and follow the manufacturer’s troubleshooting guidelines. Regular maintenance of surge arresters helps prevent potential electrical failures. Refer to the following table to quickly identify and resolve potential issues:

Symptom

Possible Causes

Troubleshooting Methods

Not Protective

Surge arrester is too far from protected equipment

Add a surge arrest device within 30m or shorten the distance between devices

Loose or improper wiring

Carefully strip and tighten connection screws

Unreliable or high ground impedance

Establish a reliable ground connection and reduce ground impedance

Mismatched working voltage

Replace the surge arrester with a model compatible with the protected equipment

Persistent Tripping

Frequent voltage spikes

Investigate the source of electrical disturbances

Overloaded circuit

Evaluate and potentially redistribute electrical load

Visual Damage

Physical signs of wear or burn marks

Immediate replacement required

Conclusion

Successfully installing the NXU-IIG Surge Arrester requires precise preparation and methodical execution. The above-listed guidelines have presented all the key stages. These include disconnecting power and selecting appropriate tools. Then the next phase is mounting the device correctly and ensuring proper wiring and connections. At CHINT, we are committed to helping you protect your electrical systems with confidence. Our experts are always ready to provide the assistance you need to ensure a safe and successful installation. Visit our website to contact our customer support for expert assistance or additional guidance.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.