Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Choose your country & Language

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.

How to Install NS2-25 Motor Starter

FEB 11, 2025

Table of Contents

  1. Essential Preparation for Installing NS2-25 Motor Starter
  2. Installation Process of the NS2-25 AC Motor Starter
  3. How to Test the NS2-25 Motor Starter
  4. Conclusion

Motor starters are essential components in electrical systems. They protect motors from potential damage and control their operational sequences. The NS2-25 Motor Starter is a robust, compact device. It’s designed for reliable motor control and protection. However, installing it may seem overwhelming. This article provides step-by-step guidance to help ensure its successful installation.

Essential Preparation for Installing NS2-25 Motor Starter

Installing this AC motor starter requires careful planning. Completely disconnect the power supply from the electrical circuit before proceeding with installation.

Then, gather the right tools for a smooth installation process. Here are the essential tools you’ll need:

  • Wire strippers
  • Crimping tools
  • Appropriately sized wires
  • Wire lugs
  • Screwdrivers
  • Insulated gloves
  • Multimeter

Installation Process of the NS2-25 AC Motor Starter

Following the correct procedure ensures this 3 phase motor starter functions effectively and safely.

1. Product Testing

Testing the product before installation helps verify its operational integrity. Use the ON and OFF buttons to check whether the starter can be connected and disconnected smoothly.

Then, use the TEST button by toggling the product in the arrow’s direction. Simultaneously press the ON button to confirm normal connection and disconnection processes.

Pay close attention to the starter’s response, noting any unusual sounds or resistance during the operation.

2. Alignment and Insertion

Precise alignment is crucial for proper installation. Position the bottom of the starter with the lower edge of the DIN rail. Then, push upward to the upper edge.

Double-check the alignment by gently pulling the starter to confirm it’s firmly locked in place.

For removal, use a flat-head screwdriver to lift the stopper. Lift the actuator’s top, separate it from the DIN rail, and tilt backward at an angle.

3. Wire Preparation

Select wires with cross-sectional areas matching the product’s current rating. Refer to these:

In(A)

NS2-25

S(Cu) mm(2)

1~6

Strip 10 mm of the copper wire using wire strippers. Ensure the exposed wire length is moderate and consistent. Inspect the stripped wire for any fraying or damage that might compromise the connection.

4. Crimping Connections

Use wire crimping pliers to attach wire lugs to copper wire ends. This creates reliable, secure electrical connections.

Perform a gentle tug test after crimping to verify the integrity of the connection.

5. Terminal Identification

The next step is to identify terminals. Refer to these:

  • 1/L1, 3/L2, and 5/L3 as primary circuit incoming terminals.
  • 2/T1, 4/T2, and 6/T3 serve as primary circuit outgoing terminals.

Use colored tape or markers to clearly label these terminals to prevent confusion during future maintenance (optional).

6. Wire Tightening

Employ an electric torque screwdriver to tighten wires to the specified torque value. Proper tightening ensures connection stability and safety. Refer to these:

Model Number

NS2-25

Fastening Screw Size

M4

Tightening Torque (N.m.)

1.7

How to Test the NS2-25 Motor Starter

Testing the NS2-25 3 phase motor starter is a critical step to ensure its proper functionality and reliability. Follow these guidelines:

  • After powering on the system, use the button next to TEST to toggle the product in the direction of the arrow. Verify its ability to disconnect normally.
  • Conduct a continuity test using a multimeter. This helps confirm the starter is working as expected and provides a comprehensive assessment of its operational integrity.

In case of installation or operational issues, refer to the troubleshooting guide. The following are some common problem scenarios and troubleshooting methods:

Problem 1: Starter Doesn’t Work

  • Potential Cause: Incorrect wire cross-section or improper connection.
  • Troubleshooting Method: Carefully review wire specifications, ensuring they match the AC motor starter’s current rating. Re-check all connections and verify they meet manufacturer guidelines.

Problem 2: No Power Supply

  • Potential Cause: Insufficient wire end stripping or loose connections.
  • Troubleshooting Method: Re-strip wire ends, ensuring clean and appropriate exposure. Verify all terminal connections are tight and secure. Check the incoming power supply with a multimeter.

Problem 3: Premature Starter Malfunction

  • Potential Cause: Mismatched current settings between starter and motor.
  • Troubleshooting Method: Fine-tune the starter’s current setting to precisely match the actual motor’s operating current. Consult the motor’s specifications and adjust accordingly.

Conclusion

Installing an NS2-25 3 phase motor starter requires careful preparation. Precise execution and thorough testing are crucial. By following the above guidelines, you can ensure a safe and efficient installation. At CHINT, we provide reliable technological solutions. Our expert technical support can assist you with any installation challenges. Browse our website to explore our electrical solutions.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.