Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

What is the Difference between Auxiliary and Main Contacts

JAN 11, 2022

difference-between-auxiliary-and-main-contacts-20220111
difference-between-auxiliary-and-main-contacts-20220111
difference-between-auxiliary-and-main-contacts-20220111

Table of Contents

  1. What is an auxiliary contact? 
  2. How does auxiliary contactor work? 
  3. Why use an auxiliary contactor? 
  4. Difference between Auxiliary and Main Contacts in Contactor? 
  5. Conclusion

Contactors have auxiliary contacts and main contacts, auxiliary contact is the contact in the auxiliary circuit that is operated mechanically. It is physically linked to the main contacts and activated at the same time. It does not carry so much current. Auxiliary contact is also referred to as supplementary contact or control contact.

What is an auxiliary contact?

An auxiliary contact (or switch) is an additional contact that forms a part of a circuit to increase the amount of electricity that can flow through the system. These are usually installed when there is already some primary source, but too much power needs to pass through for just one auxiliary contact to handle.

At least two contacts are required for this system to operate. When only one auxiliary was present, it would be possible for more current than the entire path could handle to move through one spot on the circuit.

That means that some areas would not get any electricity while others receive far more than they should. With two or more contacts present, it’s possible to limit the amount of electricity that goes through each path, making sure everything is properly powered.

How does auxiliary contactor work?

Typically, the wire to the relay or fuse may burn when an overload trips a relay or fuse. If that happens often, it could cause smoke in your system. An auxiliary contactor allows one switch to control another (usually larger) switch.

The auxiliary contactor has a coil with high-power contacts inside and two sets of low current contacts on either end. The “low voltage” set of contacts is usually labeled as such.

In contrast to the main power contactor coils rated for continuous duty throughout an entire plant, auxiliary contactors have time delay features that prevent arcing and possible damage if the auxiliary contactor opens while the main contractor is still energized.

Why use an auxiliary contactor?

1. They protect your circuit breakers (and equipment) from damage

Since auxiliary contactors release a circuit’s overloads, they ensure that the main breaker or fuse isn’t being worked too hard. That helps protect equipment from damage due to current spikes and heat buildup caused by under-capacity fuses and breakers.

In addition, auxiliary contactors help increase circuit breaker life expectancy. Auxiliary contactors are often equipped with their fuses, so if they are overloaded by an event short-circuit, the auxiliary contactor will blow its fuse without affecting the main circuit breaker.

The auxiliary contactor saves equipment from dangerous situations resulting from under-capacity or constantly tripping circuit breakers.

2. They offer enhanced protection against electrical hazards

Auxiliary contactors ensure that dangerous electrical malfunctions don’t occur because overloads have been released. If an overload isn’t released, it can cause failures in circuits and result in shocks or fire hazards due to overheating components. Auxiliary contactors minimize these risks and allow for a more secure work environment.

3. They minimize electrical failure risks

Auxiliary contactors ensure that there isn’t a high load on the circuit breaker, which minimizes the risk of electrical failures. An overloaded circuit will quickly work to blow its fuses or breakers, and this situation can cause overheating and other malfunctions that result in equipment damage and electrical injuries.

Auxiliary contactors release overloads when they reach a certain level, allowing for optimal performance and life expectancy for an electrical system.

4. They help increase circuit breaker life expectancy

If auxiliary contactors didn’t exist, main circuit breakers would be working harder to handle the extra current needed by under-capacity circuits, which would worsen their heat dissipation capabilities.

In time, this would lead up to the deterioration of the circuit breaker and negatively affect its performance. Auxiliary contactors act as current relief valves that ensure the main circuit breakers aren’t exposed to dangerous overloads, which allows them to operate more securely.

Difference between Auxiliary and Main Contacts in Contactor?

1. Main or Power Contacts in Contactor

The main contact uses an insulating disk that separates the two sets of contacts. To make a connection requires a lot more force since both parts of the device must squeeze together until they connect. That makes them especially useful when there is a need for high amperage and voltage protection on circuit breakers and switches.

Main operating contacts are used to control the operation of motor-operated equipment such as switches, circuit breakers, and contactors. The most common example is an AC contactor with both main and auxiliary contacts.

A spring mechanism between the two sets of contacts holds them apart during normal conditions when power is not applied to the device. When the switch or circuit breaker opens, it releases this spring, causing both contacts to come together and operate the coil to close the device again.

chint-auxiliary-contacts-20220111
chint-auxiliary-contacts-20220111
chint-auxiliary-contacts-20220111

2. Auxiliary Contacts in Contactor

The alarm auxiliary contacts do not require as much pressure to be applied. The two sets of contacts are touching each other due to the metal piece that holds them apart at-rest position.

When there is a problem with the AC contactor’s mechanism or if it detects an overload condition, it causes one set of contacts to separate slightly from the other. That allows for voltage to be passed through the device so that protective measures can be taken, including opening the main contacts or disengaging them completely.

Auxiliary contacts are used to monitor conditions so that if they are not operating properly, the main contacts can be opened before there is a problem with the equipment or circuit breaker.

When the auxiliary contact switch is closed, it causes an increase in heat at the contactor’s operator mechanism due to the resistance created by the current flowing through both sets of contacts. This additional heat indicates something is wrong and will give an electrical worker sufficient warning time before a serious situation develops.

Auxiliary contacts also provide overload protection for motors and hydraulic systems, which can cause pipe or valve damage if pressure exceeds certain levels. They can function as pilot lamps on larger devices such as motor control centers (MCCs) or other types of switchgear.

Conclusion

Auxiliary contacts serve several purposes for motor-operated devices and electrical professionals regarding safety and protection against electrical faults. If you need auxiliary contact, CHINT is one of the best companies you should contact since they focus on developing intelligent, reliable, and efficient electrical products.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.