Por favor, introduzca palabras clave para buscar

Global |EN

Elige tu país e idioma

Asia Pacífico

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam

Oriente Medio y África

CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN

Europa

España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido

América del norte

México

América Latina

Brasil
Colombia
Ecuador
Perú
Baja tensión
Aparatos de conmutación de baja tensión y software
Carga de vehículos eléctricos
Telecomunicaciones y Data centers
Edificios
Centro de servicio
Contáctenos
Llámanos +57 (601) 712-5419
Envíenos un correo electrónico infoco@chintglobal.com
Acerca de CHINT
Centro de noticias
Carreras

Elige tu país e idioma

Australia y Nueva Zelanda
India
Indonesia
Corea
Malasia
Filipinas
Singapur
Singapur (luz del sol)
Vietnam
CHINT-EGEMAC
Arabia Saudita
Sudáfrica
Emiratos Árabes Unidos
CHINT AJLAN
España
Francia
Kazajstán
Italia
Netherlands
Pavo
Reino Unido
México
Brasil
Colombia
Ecuador
Perú

Por favor, introduzca palabras clave para buscar

Su término de búsqueda contiene palabras clave restringidas. Utilice otras palabras clave.

Air Circuit Breaker: Features and Functions

OCT 20, 2023

Air Circuit Breaker Features and Functions
Air Circuit Breaker Features and Functions
Air-Circuit-Breaker-Features-and-Functions

Table of Contents

  1. What is an Air Circuit Breaker?
  2. Features of Air Circuit Breaker
  3. Working Principles and Functions
  4. Air Circuit Breakers: Maintenance Tips
  5. Conclusion

Circuit breakers have been used for decades to prevent power surges and failures due to circuits overloading. Traditionally, they use a fuse that must be replaced after every use. However, air circuit breakers have recently grown in popularity due to their enhanced features and functions.

What is an Air Circuit Breaker?

An air circuit breaker is an important safety equipment for any electrical line. It is a switch that operates automatically whenever a power surge or other fault is detected. It is designed to prevent the system from overloading, which can potentially ruin devices plugged into the power source or start a fire.

The circuit breaker was first theorized by Thomas Edison in 1879, although the first model to use air instead of an electrical fuse was not invented until 1949 by the American electrical company Westinghouse. Other models have used oil to break up the electricity as well. They are generally considered by experts to be superior to other forms of circuit breakers.

Features of Air Circuit Breaker

Although there are many different manufacturers and styles, the primary features are generally the same from unit to unit. There are four types of ACBs. But for the purposes of this article, we will be focusing primarily on the Air Blast version.

The frame of an ACB usually refers to the outer shell, which is made of aluminum, chromium steel, or another type of sturdy metal that protects the internal components from dust and other environmental damage. However, it can also refer to the internal insulating frame, which is accompanied by an insulating plate, which houses and protects the contacts.

An ACB will also generally feature two pairs of contacts, although larger industrial units may have more. The first set is usually made of copper and is used to conduct electricity along its normal path during normal operation. The second set is made of carbon and is used as a failsafe to prevent excess electricity from the first pair from being able to do any damage.

An air circuit breaker’s arc chute is a pathway designed to contain the arc and keep its path out of the way of the rest of the internal mechanisms. It uses insulation to perform this task because it does not conduct electricity and can be absorbed harmlessly into the insulating material.

The main operating mechanism is, as the name suggests, the part that allows the unit to function as intended. This part shoots out of the burst of compressed air. It prevents the electrical arc from reforming until the voltage is low enough that the underlying system can handle it without overloading.

Working Principles and Functions

The primary function of an ACB is to prevent an arc of electricity from reforming when its voltage becomes too high for the system to handle. Unlike traditional models that use a fuse or oil, they use bursts of compressed air to disrupt the electrical impulses and keep the voltage entering the system from becoming high enough to be dangerous.

They also prevent an electrical arc from overloading the system after a power surge or another event. This can happen in various ways but the most common is after a power outage. When the city grid is restored and the electricity begins to flow again, it can overwhelm a system that isn’t prepared for it.

ABCs also prevent short circuits, which can cause overheating, electrical fires, or even explosions. These are caused by an imbalance between the voltage of two separate circuits, which makes the current go the wrong way. An ACB will stop the flow of electricity before any of those things can happen.

They also create isolation as another means of protection, which is an electrical term that refers to the act of stopping corrosion. These systems can easily become corroded without proper isolation because of stray currents created by the different types of metal used.

This is one of the major functions of the insulation used in these systems, which absorbs the extra electricity and is not conductive, meaning those electrical charges will disappear harmlessly.

You may be interested in this blogpost

    Why You Need an Air Circuit Breaker for Your Equipment

     Learn More »

Air Circuit Breakers: Maintenance Tips

Like all machines, an ACB will require proper care to ensure it continues operating at peak performance. One of the best ways to achieve this is by regularly maintaining the unit. Here are a few things to keep in mind for each maintenance period, which should be at regular intervals, a couple of times per year at minimum.

The first thing to do is to check to see that the insulation inside the unit is dry, as wet insulation is not only less effective but is a breeding ground for mold. A handheld vacuum can be used to clean it or a lint-free rag or towel will work. You’ll also want to check all the parts for potential damage.

The next step is to check the contacts to make sure that they have no signs of rust or damage. If you have access to a micro-ohmmeter, you should also check to make sure that the contacts are still functioning properly. Finally, you’ll want to ensure everything has the correct alignment.

Most importantly, the machine should be checked for dryness, except the operating mechanism, which should be properly lubricated.

Conclusion

By understanding the features and functions of an ACB, users will better understand which type will work best for their particular situation. Chint Global Products has sold high-quality air circuit breakers and electrical supplies in general for over 40 years, making them the perfect choice for first-time ACB purchasers.

Lo último
MAY 6, 2025 NGC5 Diseñado para la excelencia, fabricado para la fiabilidad

NGC5 Original Manufactured LV Switchgear es el nuevo tipo de montaje de prueba elaborado por CHINT. Establece un nuevo punto de referencia para la fiabilidad y la eficiencia.

APRIL 22, 2025 Cómo protege el magnetotérmico NM8N-HV las salidas de CA de los sistemas solares

El disyuntor de caja moldeada NM8N-HV proporciona una protección esencial para las salidas de CA en sistemas de energía solar contra cortocircuitos y sobrecargas.

APRIL 15, 2025 What is a New Energy Air Switch Disconnector: Facts You Need to Know

Discover how the new energy air switch disconnector (solar disconnector switch) plays a crucial role in ensuring safety and reliability in utility-scale solar and battery energy storage systems (BESS).

APRIL 2, 2025 Experience Smooth Motor Starting with CHINT’s NJRP5-D Soft Starter

This article focuses on CHINT’s NJRP5-D Soft Starter and explores its functionality and advantages.

MARCH 26, 2025 Celda de media tensión GIS RMU CHINT 36/40,5kV: Nuevas aplicaciones energéticas con soluciones innovadoras

La celda de media tensión RMU CHINT no sólo resuelve los retos técnicos y medioambientales, sino que también mejora la eficacia operativa y la rentabilidad de los clientes.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

MARCH 18, 2025 Miniature Circuit Breaker: Understanding UL 489 and UL 1077

This article specifies the key differences between UL 489 and UL 1077, helping choose suitable Miniature Circuit Breakers.

MARCH 17, 2025 IEC frente a UL: Comprender las normas de certificación de disyuntores de aire

Compare la certificación IEC frente a la UL para disyuntores de aire: normas regionales, cumplimiento de las normas de seguridad y soluciones con certificación mundial de CHINT para una protección eléctrica fiable.

MARCH 5, 2025 Guide to Air Circuit Breaker Maintenance

This guide discovers essential inspection, cleaning, and testing procedures of the air circuit breaker to prevent failures and extend equipment lifespan.

FEBRUARY 26, 2025 The Basics of NVF2L Compact Micro Drive

NVF2L Compact Micro Drive is designed to meet the growing demand for efficient, space-saving solutions in various industrial applications. Explore CHINT's industrial drive technology solutions.