Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
SHT-X3 Shunt Release
SHT X3 Accessories (Final Power Distribution) Front
SHT X3 Accessories (Final Power Distribution) Side
SHT X3 Accessories (Final Power Distribution)
SHT X3 Accessories (Final Power Distribution) Front
SHT X3 Accessories (Final Power Distribution) Side
SHT X3 Accessories (Final Power Distribution)

SHT-X3 Shunt Release

The SHT-X3 Shunt Release is designed to provide remote trip functionality for the NXB-125 circuit breaker. When energized, it immediately trips the breaker to disconnect the circuit, ensuring fast fault isolation and enhanced safety. Operating reliably within 70%–110% of the rated control voltage, the SHT-X3 offers a rated insulation voltage of 500V, mechanical life of over 4000 cycles, and easy assembly via TH35-7.5 DIN rail mounting, making it an ideal accessory for remote control and automation systems.

Product Information

Recommend Blogs
DECEMBER 8, 2025 Integrating Renewable Energy into Existing Grid Networks

Integrate renewables smoothly with modern power transformer solutions that stabilize voltage, support bidirectional flow, and strengthen grid reliability for clean energy growth.

DECEMBER 5, 2025 A Complete Guide to Selecting MCBs and RCCBs for Modern Buildings

Discover how to choose the right devices in the MCB vs RCCB lineup for safer, more reliable systems. Learn practical steps to strengthen electrical protection in modern buildings.

JULY 1, 2025 Understanding the VFD Working Principle in Industrial Automation

Learn the working principle of VFDs and discover how CHINT NVF7 boosts performance, energy savings, and equipment longevity in industrial automation.

JUNE 25, 2025 RCBO Breakers Explained: How They Work, Wiring Diagrams, and Testing Tips

Discover how RCBO breakers protect against overloads and Earth leakages. Learn about wiring diagrams, differences from MCBs, and testing tips for safe operations.

JUNE 9, 2025 What Is A Pulse Relay and How Does It Work?

Explore the energy-efficient pulse relay technology used in automation, lighting, and security systems. Featuring CHINT’s NJMC1 relay for reliable performance.

MAY 22, 2025 CHINT Electric Solutions: Empowering Green and Smart Buildings

The article highlights CHINT Electric Solutions' role in advancing green and smart buildings through innovative, reliable electrical systems that enhance energy efficiency, sustainability, and smart functionality across modern construction projects.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

FEBRUARY 12, 2025 How to Install NM8N Molded Case Circuit Breaker

This article provides step-by-step guidance to help ensure the successful installation of the NM8N Molded Case Circuit Breaker.

JANUARY 20, 2025 How to Install NXB-63 Miniature Circuit Breaker

This guide provides step-by-step instructions for the proper installation, wiring, and testing of the NXB-63 MCB to ensure optimal performance and safety.

SEPTEMBER 9, 2024 How to Choose a House Distribution Box

A well-chosen distribution box ensures the safety and efficiency of your household electrical system. This article guides you through selecting a distribution box.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the function of the SHT-X3 Shunt Release?

The SHT-X3 provides remote tripping capability for NXB-125 circuit breakers. When voltage is applied, it releases the mechanism, causing the breaker to trip and safely disconnect the circuit.

 

How does the SHT-X3 indicate its operational status?

When open, terminals C2–12 are connected to light the security indicator; when closed, terminals C2–14 light the warning indicator. Upon tripping, the trip indicator visibly marks breaker status.

 

What voltages can the SHT-X3 operate under?

It supports AC 400V, 230V, and AC/DC 48V or 24V, functioning reliably within 70%–110% of its rated supply voltage.

 

How is the SHT-X3 installed?

It easily assembles on the left side of the NXB-125 breaker, then mounts on a TH35-7.5 DIN rail.

 

What makes the SHT-X3 suitable for industrial and automation systems?

Its remote control capability, long mechanical life (≥4000 cycles), and compatibility with control indicators make it ideal for automated monitoring and protective control systems.