Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NB8LE-63M Residual Current Operated Circuit Breaker with over-current protection (Electronic)
NB8LE-63M Residual Current Operated Circuit Breaker with over-current protection (Electronic)
NB8LE-63M Residual Current Operated Circuit Breaker with over-current protection (Electronic)

NB8LE-63M Residual Current Operated Circuit Breaker with over-current protection (Electronic)

The CHINT NB8LE-63M RCBO integrates residual current and over-current protection in one compact unit, providing comprehensive safety for modern electrical systems. Designed for residential, commercial, and industrial applications, it effectively protects against earth leakage, overload, and short circuits. The NB8LE-63M features electronic detection, high breaking capacity, and quick disconnection for user safety. Built to IEC/EN 61009-1, it ensures precise protection performance, easy DIN-rail installation, and reliable operation across various voltage and load conditions.

Product Information

Recommend Blogs
DECEMBER 8, 2025 Integrating Renewable Energy into Existing Grid Networks

Integrate renewables smoothly with modern power transformer solutions that stabilize voltage, support bidirectional flow, and strengthen grid reliability for clean energy growth.

DECEMBER 5, 2025 A Complete Guide to Selecting MCBs and RCCBs for Modern Buildings

Discover how to choose the right devices in the MCB vs RCCB lineup for safer, more reliable systems. Learn practical steps to strengthen electrical protection in modern buildings.

JULY 1, 2025 Understanding the VFD Working Principle in Industrial Automation

Learn the working principle of VFDs and discover how CHINT NVF7 boosts performance, energy savings, and equipment longevity in industrial automation.

JUNE 25, 2025 RCBO Breakers Explained: How They Work, Wiring Diagrams, and Testing Tips

Discover how RCBO breakers protect against overloads and Earth leakages. Learn about wiring diagrams, differences from MCBs, and testing tips for safe operations.

JUNE 9, 2025 What Is A Pulse Relay and How Does It Work?

Explore the energy-efficient pulse relay technology used in automation, lighting, and security systems. Featuring CHINT’s NJMC1 relay for reliable performance.

MAY 22, 2025 CHINT Electric Solutions: Empowering Green and Smart Buildings

The article highlights CHINT Electric Solutions' role in advancing green and smart buildings through innovative, reliable electrical systems that enhance energy efficiency, sustainability, and smart functionality across modern construction projects.

MARCH 21, 2025 Single Phase vs Three Phase Voltage Regulator

This article explains the differences between single phase voltage regulators and three phase voltage regulators.

FEBRUARY 12, 2025 How to Install NM8N Molded Case Circuit Breaker

This article provides step-by-step guidance to help ensure the successful installation of the NM8N Molded Case Circuit Breaker.

JANUARY 20, 2025 How to Install NXB-63 Miniature Circuit Breaker

This guide provides step-by-step instructions for the proper installation, wiring, and testing of the NXB-63 MCB to ensure optimal performance and safety.

SEPTEMBER 9, 2024 How to Choose a House Distribution Box

A well-chosen distribution box ensures the safety and efficiency of your household electrical system. This article guides you through selecting a distribution box.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the function of the NB8LE-63M RCBO?

It provides integrated protection against overloads, short circuits, and residual current faults (earth leakage), ensuring both circuit and personal safety.

 

In what type of applications can it be used?

The NB8LE-63M is suitable for residential buildings, offices, and industrial control systems, especially where reliable leakage protection and selective tripping are needed.

 

What is the difference between Type AC and Type A residual current protection?

Type AC detects sinusoidal AC leakage currents.

Type A detects both sinusoidal AC and pulsating DC leakage currents, suitable for electronic loads and inverter-based equipment.

 

What are the available current ratings and breaking capacities?

The device offers rated currents from 6 A to 63 A with a 10 kA breaking capacity, meeting high-demand installation requirements.

 

Can the NB8LE-63M be combined with accessories?

Yes. It supports auxiliary contacts, shunt releases, and under-voltage releases, allowing integration with automation and monitoring systems.