Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

Saudi Arabia
South Africa
UAE
Egypt
Kenya

Europe

France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom

North America

Mexico
USA
Canada

Latin America

Brazil
Colombia
Ecuador
Peru
Low-voltage
Instruments and Meters
EV Charging
Telecom & Data Center
Buildings
Products
Solutions
Project References
Corporate Reports
CHINT Global
CHINT's Insights
Careers
Locate Us
Contact Us
Call Us +65 6329 3110
Email Us sales.apac@chint.com
Privacy Policy
Online Services

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
Saudi Arabia
South Africa
UAE
Egypt
Kenya
France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom
Mexico
USA
Canada
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
OUVT-X1 Over-under Voltage Release
OUVT X1 Accessories (Final Power Distribution) Front
OUVT X1 Accessories (Final Power Distribution) Side 1
OUVT X1 Accessories (Final Power Distribution) Side 2
OUVT X1 Accessories (Final Power Distribution)
OUVT X1 Accessories (Final Power Distribution) Front
OUVT X1 Accessories (Final Power Distribution) Side 1
OUVT X1 Accessories (Final Power Distribution) Side 2
OUVT X1 Accessories (Final Power Distribution)

OUVT-X1 Over-under Voltage Release

The OUVT-X1 Over-under Voltage Release is a key accessory designed to be assembled with circuit breakers NXB-63 or NXB-40 to provide automatic protection against abnormal voltage conditions. It precisely trips the breaker when voltage is too low or too high and crucially prevents reclosing until the voltage returns to a safe range. This ensures circuit stability and vital equipment safety, safeguarding sensitive loads from damaging fluctuations. With adjustable trip settings and delay times, the OUVT-X1 offers an integral solution for enhancing safety and reliability across residential, commercial, and industrial applications.

Product Information

Recommend Blogs
MARCH 10, 2026 How Surge Protective Devices (SPDs) Keep Your Small Business Equipment Safe

Learn how surge protection and electrical protection strategies support small business power needs, reduce downtime, and keep equipment reliable as demand grows.

MARCH 9, 2026 Maintaining Electrical Safety Across Distributed Infrastructure

Learn how smart maintenance strategies protect electrical safety across distributed facilities, reducing downtime and keeping multi-site operations predictable and reliable.

MARCH 8, 2026 How Automated Distribution Systems Improve Network Stability

Grid automation allows for better management of distribution systems and your network. See how automated distribution systems improve outage management.

MARCH 7, 2026 Why Certification Matters in High-Voltage Equipment

Learn why IEC standards and electrical safety certification matter for high-voltage equipment, improving reliability, protection accuracy, and risk control across power networks.

MARCH 6, 2026 Ensuring Continuous Power Supply in Critical Infrastructure Like Airports

Ensure reliable airport power with robust critical power systems and layered resilience. Explore how redundancy, monitoring, and design keep aviation operations running smoothly.

FEBRUARY 14, 2026 Designing with IEC 61439-Compliant Switchgear for Better LV Assembly Performance

Designing an IEC switchboard is necessary for every operation, whether industrial or commercial. Acquiring IEC 61439 design verification for MDBs is important.

FEBRUARY 12, 2026 Selecting the Right Control Components for High-Inrush Loads

Learn how to choose the proper control components like MCCB, overload relay, and contactors used in high inrush load for motor protection.

FEBRUARY 12, 2026 How Smart Meters Help Optimize Building Energy Use

Great building energy management makes use of smart meters to gauge energy consumption. Learn why smart metering is a sign of good energy monitoring practice.

SEPTEMBER 23, 2025 Manual Motor Starter: A Guide for Safer Motor Control

Every electric motor needs protection against fault conditions. In this article, learn how a manual motor starter helps you achieve this requirement.

AUGUST 1, 2025 Slim RCBO Solutions for Power Distribution: CHINT NB1L-20 for Compact, Compliant Installations

CHINT’s NB1L-20 is a great addition to any power distribution system. Learn why you should consider our product if you value safety and compliance.

Helpful Links

Blog
Blog

Explore expert insights, trends, and CHINT perspectives on the smart energy industry.

Read More
Resources
Resources

Download essential CHINT resources for your business needs.

Download Now
Contact Us
Contact Us

Have questions? Contact us for support and solutions.

Get Support
Collapsed
Expand

FAQs

 

What is the main function of the OUVT-X1?

It provides automatic protection against dangerous voltage fluctuations by disconnecting the circuit breaker during over-voltage or under-voltage conditions, ensuring equipment safety.

 

Which circuit breakers is it compatible with?

The OUVT-X1 is designed for CHINT’s NXB-63 series circuit breakers, easily attaching to the left side of the unit for fast installation.

 

How does it determine trip conditions?

Trips when voltage drops below 35% Ue or exceeds 105% of the 280V over-voltage setting.

Allows breaker closure only within safe limits (85%–95% of rated voltage).

 

How is the OUVT-X1 installed?

It is mounted on a TH35-7.5 DIN rail, connecting directly to the NXB-63 circuit breaker. Installation is quick and requires minimal wiring adjustments.

 

What is its service life?

The unit has a mechanical and electrical life of over 4000 cycles, ensuring reliable long-term performance under normal and fault conditions.