Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
Egypt
Kenya

Europe

France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom

North America

Mexico

Latin America

Brazil
Colombia
Ecuador
Peru
Low-voltage
Power Transmission and Distribution
Low Voltage Switchgear and Software
Instruments and Meters
Telecom & Data Center
Buildings
Products
Solutions
Project References
Corporate Reports
CHINT Global
CHINT's Insights
Careers
Locate Us
Contact Us
Call Us +91 1202 9750 57
Email Us marketing@chint.co.in
Privacy Policy

Choose your country & Language

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
Egypt
Kenya
France
Kazakhstan
Italy
Netherlands
Spain
Turkey
United Kingdom
Mexico
Brazil
Colombia
Ecuador
Peru

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NB2LE Residual Current Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker

NB2LE Residual Current Operated Circuit Breaker

The NB2LE Residual Current Operated Circuit Breaker (RCBO) offers essential personnel and fire protection by combining reliable overload, short-circuit, and earth leakage fault protection in one device. NB2LE RCBO automatically disconnects power to prevent electric shock and electrical fires, ensuring electrical safety in industrial, commercial, high-rise buildings, and residential applications.

Product Information

Recommend Blogs
AUGUST 22, 2025 MCCB Frame Sizes Explained: Choosing the Right Circuit Breaker for Industrial Loads

Circuit breakers are important in any electrical system. Learn about MCCB frame sizes to select the correct circuit breaker for industrial loads.

AUGUST 14, 2025 Customized Electrical Components with Better Adaptability, Better Meet Customer Needs

CHINT offers customized OEM electrical solutions with global compliance, fast delivery, and superior adaptability for HVAC, DG, and elevator applications.

AUGUST 11, 2025 From Certification to Application: How CHINT M1 MCCB Supports OEM Success Stories

CHINT M1 MCCB: UL489-certified, high-capacity, versatile breaker powering OEM success in HVAC, solar, industrial & more.

AUGUST 1, 2025 Slim RCBO Solutions for Power Distribution: CHINT NB1L-20 for Compact, Compliant Installations

CHINT’s NB1L-20 is a great addition to any power distribution system. Learn why you should consider our product if you value safety and compliance.

JULY 14, 2025 UL Certification Requirements for OEMs: Essential Guide for Renewable Energy Projects in 2025

UL Certification Requirements for OEMs: Essential Guide for Renewable Energy Projects in 2025

JULY 10, 2025 Configuration Guide: Setting Up the CHINT SMG-WSR and SMG-ESR Open Protocol Gateway

Step-by-step protocol gateway setup guide for CHINT SMG-WSR and SMG-ESR, covering wiring, network configuration, and MQTT cloud connection.

JULY 2, 2025 A Guide to the CHINT SMG Open Protocol Gateway: Building Flexible IoT Solutions

Discover how CHINT’s SMG-WSR/SMG-ESR Gateway and NB2 Circuit Breakers create smart, efficient, and remote-controlled electrical systems for various industries.

JULY 1, 2025 An Introduction to Power Circuit Breakers: How Do They Protect Your Industrial and Commercial Facilities?

Explore CHINT’s power circuit breaker solutions for high-performance electrical protection in industrial, commercial, and healthcare environments.

JULY 1, 2025 Understanding the VFD Working Principle in Industrial Automation

Learn the working principle of VFDs and discover how CHINT NVF7 boosts performance, energy savings, and equipment longevity in industrial automation.

JUNE 30, 2025 Gas Insulated Switchgear in Renewable Energy Integration

Learn how CHINT’s gas-insulated switchgear ensures stable, safe, and compact power distribution in renewable energy projects like wind and solar farms.

Helpful Links

Blog
Blog

Explore expert insights, trends, and CHINT perspectives on the smart energy industry.

Read More
Resources
Resources

Download essential CHINT resources for your business needs.

Download Now
Contact Us
Contact Us

Have questions? Contact us for support and solutions.

Get Support
Collapsed
Expand

FAQs

 

What is the main function of the NB2LE RCBO?

It integrates overload, short-circuit, and residual current protection in one unit. When leakage or electric shock occurs, it disconnects the circuit instantly to prevent harm to people and damage to equipment. 

 

What configurations and tripping types are available?

NB2LE is available in 1P+N configuration, with Type B and Type C tripping curves to suit different load conditions. Type B suits resistive loads; Type C handles inductive loads such as motors. 

 

What leakage current ratings can be selected?

You can choose rated residual currents of 30 mA, 100 mA, or 300 mA to match protection needs — from personal safety to fire prevention and system protection. 

 

Can the NB2LE be mounted on standard DIN rails?

Yes. The RCBO is designed for quick DIN rail (TH35-7.5) installation, making it compatible with modern electrical panels. 

 

What types of circuits is this RCBO suitable for?

It supports AC 230/240 V, 50/60 Hz systems and is ideal for residential, commercial, and industrial circuits where personnel and equipment protection are critical.