Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam

Middle East & Africa

CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
Egypt
Kenya

Europe

France
Italy
Spain
Turkey
Kazakhstan
Netherlands

North America

Mexico
USA
Canada

Latin America

Brazil
Peru
Ecuador

Choose your country & Language

Australia & New Zealand
India
Indonesia
Korea
Malaysia
Philippines
Singapore
Singapore (Sunlight)
Vietnam
CHINT-EGEMAC
Saudi Arabia
South Africa
UAE
CHINT AJLAN
Egypt
Kenya
France
Italy
Spain
Turkey
Kazakhstan
Netherlands
Mexico
USA
Canada
Brazil
Peru
Ecuador

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NB2LE Residual Current Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker
NB2LE Residual Current  Operated Circuit Breaker

NB2LE Residual Current Operated Circuit Breaker

The CHINT NB2LE Residual Current Operated Circuit Breaker (RCBO) provides combined protection against overload, short-circuit, and residual current faults in AC 230/240 V circuits. Designed for industrial, commercial, and residential applications, it automatically disconnects the power supply upon leakage or electric shock, ensuring maximum safety. With 6 kA breaking capacity, multiple tripping curves, and leakage sensitivities from 30 to 300 mA, the NB2LE is reliable, compact, and compliant with IEC/EN 61009-1 standards.

Product Information

Recommend Blogs
OCTOBER 15, 2025 Guide to MCB Trip Curves: Selecting the Right B, C, or D Curve for Overcurrent Protection

Solve nuisance tripping problems for good. Our guide helps you diagnose why your breaker trips on startup and shows how to select the correct B, C, or D curve for motors, pumps, and other loads.

SEPTEMBER 28, 2025 Industrial Diesel Generator Safety Devices That Keep Operations Running

Discover how diesel generator safety devices like MCCBs, ACBs, and relays ensure reliable backup power, protect facilities, and keep operations running safely.

SEPTEMBER 23, 2025 Manual Motor Starter: A Guide for Safer Motor Control

Every electric motor needs protection against fault conditions. In this article, learn how a manual motor starter helps you achieve this requirement.

AUGUST 22, 2025 MCCB Frame Sizes Explained: Choosing the Right Circuit Breaker for Industrial Loads

Circuit breakers are important in any electrical system. Learn about MCCB frame sizes to select the correct circuit breaker for industrial loads.

AUGUST 14, 2025 Customized Electrical Components with Better Adaptability, Better Meet Customer Needs

CHINT offers customized OEM electrical solutions with global compliance, fast delivery, and superior adaptability for HVAC, DG, and elevator applications.

AUGUST 11, 2025 From Certification to Application: How CHINT M1 MCCB Supports OEM Success Stories

CHINT M1 MCCB: UL489-certified, high-capacity, versatile breaker powering OEM success in HVAC, solar, industrial & more.

AUGUST 1, 2025 Slim RCBO Solutions for Power Distribution: CHINT NB1L-20 for Compact, Compliant Installations

CHINT’s NB1L-20 is a great addition to any power distribution system. Learn why you should consider our product if you value safety and compliance.

JULY 14, 2025 UL Certification Requirements for OEMs: Essential Guide for Renewable Energy Projects in 2025

UL Certification Requirements for OEMs: Essential Guide for Renewable Energy Projects in 2025

JULY 10, 2025 Configuration Guide: Setting Up the CHINT SMG-WSR and SMG-ESR Open Protocol Gateway

Step-by-step protocol gateway setup guide for CHINT SMG-WSR and SMG-ESR, covering wiring, network configuration, and MQTT cloud connection.

JULY 2, 2025 A Guide to the CHINT SMG Open Protocol Gateway: Building Flexible IoT Solutions

Discover how CHINT’s SMG-WSR/SMG-ESR Gateway and NB2 Circuit Breakers create smart, efficient, and remote-controlled electrical systems for various industries.

Need Support From Us?

Blog
Blog

Find expert perspectives on the trends and technologies driving your business.

View Now
Download Center
Download Center

Download new and previously released documents including product document, solutions, cases, coporate report.

View Now
Contact Us
Contact Us

Reach out to us to receive more information, technical support, assistance with complaints and more.

Get Support
Collapsed
Expand

FAQs

 

What is the main function of the NB2LE RCBO?

It integrates overload, short-circuit, and residual current protection in one unit. When leakage or electric shock occurs, it disconnects the circuit instantly to prevent harm to people and damage to equipment. 

 

What configurations and tripping types are available?

NB2LE is available in 1P+N configuration, with Type B and Type C tripping curves to suit different load conditions. Type B suits resistive loads; Type C handles inductive loads such as motors. 

 

What leakage current ratings can be selected?

You can choose rated residual currents of 30 mA, 100 mA, or 300 mA to match protection needs — from personal safety to fire prevention and system protection. 

 

Can the NB2LE be mounted on standard DIN rails?

Yes. The RCBO is designed for quick DIN rail (TH35-7.5) installation, making it compatible with modern electrical panels. 

 

What types of circuits is this RCBO suitable for?

It supports AC 230/240 V, 50/60 Hz systems and is ideal for residential, commercial, and industrial circuits where personnel and equipment protection are critical.