Please enter keywords to search

Global |EN

Choose your country & Language

Asia Pacific

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore

Middle East & Africa

Kenya
Saudi Arabia
South Africa
United Arab Emirates

Europe

France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom

Latin America

Brazil
Colombia
Ecuador
Peru

North America

Canada
Mexico
United States
Low-voltage
Instruments and Meters
EV Charging
Telecom & Data Center
Buildings
Products
Solutions
Project References
Corporate Reports
CHINT Global
CHINT's Insights
Careers
Locate Us
Contact Us
Call Us +61 1800 270 870
Email Us info.australia@CHINT.com
Privacy Policy
Online Services

Choose your country & Language

Australia & New Zealand
India
Indonesia
Malaysia
Philippines
Singapore
Kenya
Saudi Arabia
South Africa
United Arab Emirates
France
Kazakhstan
Netherlands
Spain
Italy
Turkey
United Kingdom
Brazil
Colombia
Ecuador
Peru
Canada
Mexico
United States

Please enter keywords to search

Your search term contains restricted words. Please use different keywords.
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)
NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)

NB3LEU Residual Current Operated Circuit Breaker with Over-current Protection (Electronic)

The NB3LEU Residual Current Operated Circuit Breaker (RCBO) is an advanced electronic device that delivers integrated overload, short-circuit, and comprehensive earth leakage protection. It accurately detects residual currents (Type A and AC class) to enhance safety against electric shock and fire hazards. Available in various current ratings, this compact RCBO ensures rapid, reliable fault disconnection, making it ideal for residential, commercial, and industrial electrical installations.

Product Information

Recommend Blogs
MAY 22, 2026 Keeping the Lights On: Power Reliability Strategies for Food & Beverage Facilities

Unplanned downtime in food manufacturing is expensive. Learn how the right electrical components prevent costly stoppages in food processing plants.

MAY 22, 2026 How to Choose the Right Generator Control System for Your Application

Choosing the wrong generator control components causes failure when it matters most. A practical guide to ATS, circuit breakers, and dual supply design.

MAY 22, 2026 Building a Reliable Microgrid: From Planning to Power-On

Plan resilient microgrid projects with practical guidance on topology, storage sizing, switchgear, islanding protection, and technical support teams.

MAY 22, 2026 Electrical Protection in Mining and Petrochemical Environments

In mining and petrochemical sites, standard LV components are never enough. A guide to hazardous area equipment, motor protection, and reliable distribution.

MAY 22, 2026 Reducing Energy Waste in Steel and Metals Manufacturing

Steel plants are among the most energy-intensive operations on earth. Here's where energy efficiency in steel manufacturing starts, and the role of the electrical system.

MAY 22, 2026 Electrical Solutions for Modern Logistics: Conveyors, Lifts, and Warehouse Automation

As e-commerce pushes warehouse automation to new heights, electrical control systems are under more pressure than ever. Here's how to specify them correctly.

MAY 22, 2026 Smarter Water Management: Electrical Control Solutions for Pumps and Water Systems

Learn how the right pump electrical control systems. From VFDs to fire pump panels, improve reliability, cut energy costs, and protect motor assets.

MAY 22, 2026 C&I Solar and Storage: What Businesses Need to Know Before Going Solar

Commercial solar has very different requirements from residential. Learn what C&I solar and storage projects really need to succeed, and what to watch out for.

MAY 22, 2026 Power Quality in Oil and Gas: Why It Matters More Than You Think

In oil and gas, poor power quality can trigger safety shutdowns and damage instrumentation. A practical guide to power quality monitoring for operations teams.

MAY 12, 2026 How Digital Substations Support the Smart Grid Transition

A practical guide to turning digital substations into observable, controllable smart grid nodes that improve restoration speed, renewable readiness, and power quality.

Helpful Links

Blog
Blog

Explore expert insights, trends, and CHINT perspectives on the smart energy industry.

Read More
Resources
Resources

Download essential CHINT resources for your business needs.

Download Now
Contact Us
Contact Us

Have questions? Contact us for support and solutions.

Get Support
Collapsed
Expand

FAQs

 

What makes the NB3LEU RCBO different from traditional breakers?

It combines leakage, overload, and short-circuit protection in one compact device using electronic tripping, offering faster response and improved reliability over purely thermal types.

 

What are Type A and Type AC sensitivities?

Type A: Detects both AC and pulsating DC leakage currents.

Type AC: Detects only sinusoidal AC leakage currents.

This ensures compatibility with various load types and system conditions.

 

Can this breaker handle high fault currents?

Yes. The NB3LEU offers a 10 kA short-circuit capacity, making it suitable for robust protection in both residential and commercial environments.

 

What installation options are available?

It can be mounted on a 35 mm DIN rail and connected via cable, U-type, or pin-type busbars, supporting flexible panel configurations.

 

Does temperature affect performance?

Performance is rated at 30 °C, but derating applies above that (e.g., 0.9 at 50 °C, 0.85 at 60 °C) to ensure safe operation in warmer environments.